CP43操作手册.pdf.pdf - 第319页

Chapter 4 V ision Processing Errors Part 6 Error Code 1C310019 Cause: Calibration is already in the pr ocess of being carried out. Remedy: This error will pr obably never occur . 4.3 V ision Processing Parts Errors Error…

100%1 / 364
Chapter 4 Vision Processing ErrorsPart 6
4.2 Calibration (Proper Data Measurement) Error Messages
Error Code 1C310010
Cause: Training cannot be carried out.
Remedy: Try rebooting the machine. This error generally does not occur.
Error Code 1C310011
Cause: A contradiction occurred during calibration.
Remedy: This error generally does not occur. Reboot the machine.
Error Code 1C310013
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 1C310015
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 310016
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 1C310017
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 310018
Cause: A contradiction occurred in the calibration operation
commands.
Remedy: This error will probably never occur. If it does, contact Fuji.
6 – 18Version 2.0
Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C310019
Cause: Calibration is already in the process of being carried out.
Remedy: This error will probably never occur.
4.3 Vision Processing Parts Errors
Error Code 1C4100004
Cause: A logical error has occurred.
Remedy: Contact Fuji or your Fuji representative.
Error Code 1C410100
Cause: There is no element.
Remedy: Check the generic device description.
Error Code 1C410101
Cause: Vision processing could not detect an edge on the element.
Remedy: Check the generic device description.
Error Code 1C410102
Cause: There is a mistake in the segment ID.
Remedy: Check the generic device description segment ID (refer to ‘id’).
Error Code 1C410103
Cause: Placement flag has not been set.
Remedy: Check the generic device description placement flag (refer to
‘placement’).
Error Code 1C410104
Cause: Pick-up error is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y,’ ‘rotational tolerance’).
6 – 19Version 2.0
Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410105
Cause: The coarse edge is not suitable.
Remedy: Check coarse edge in the generic device description .
Error Code 1C410106
Cause: Nozzle diameter is too large.
Remedy: Choose a smaller nozzle. Verify that the nozzle is one that is
used in Part data.
Error Code 1C410107
Cause: Nozzle backlight diameter is small.
Remedy: Choose a nozzle with a larger backlight. Verify that the nozzle is
entered in Part data.
Error Code 1C410108
Cause: Nozzle training (center measurement) has not been set.
Remedy: Center the nozzle.
Error Code 1C410109
Cause: Vision processing segment could not be inspected.
Remedy: Check the problem using the vision processing debug monitor.
Error Code 1C410110
Cause: L size tolerance check error.
Remedy: Change the edge tolerance
e2_tolerance, e4_tolerance, or
check the segment size l1 l_size, l2 l_size.
Error Code 1C410111
Cause: D size tolerance check error.
Remedy: Change the edge tolerance
e1_tolerance, e3_tolerance, or
check the segment size d1 d_size, d2 d_size.
6 – 20Version 2.0