CP43操作手册.pdf.pdf - 第332页
Chapter 5 Data Check Errors Part 6 Pickup Position D2 Check If this is set at less than 100000 or more than 300000, err or code 1 102233B will result. Remedy: Carry out Pr oper data measurement and then transmit the corr…

Version 2.0
Chapter 5 Data Check ErrorsPart 6
• Cam Speed Check
When "Cam_speed_CP43" is checked in Part data, and the cam speed
has not been entered the following error code will display.
11010310 + device number/13
Note: Check Part data, enter the correct value for "Cam_speed_CP43 and
retransmit the corrected program.
5.2 Checking Proper Data
Any time a Proper data item moves outside its prescribed range, an error
message will appear.
Placing Position X and Placing Position Y Check
If either of these are at 0, error code 11022321 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Loading Position X and Loading Position Y Check
If either of these are at 0, error code 11023223 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Cam Speed Check
If the cam speed is less than 10% or greater than 100%, error code
11022323 will appear.
Remedy: Enter a value within this range and transmit the corrected
Proper data. Normally this value is set at 100%.
Pickup Position D1 Check
If this is set at less than -500000 or more than 0, error code 11022326 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 31

Chapter 5 Data Check ErrorsPart 6
Pickup Position D2 Check
If this is set at less than 100000 or more than 300000, error code 1102233B
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
D1 Original Position Check
If this is set at less than -10000 or more than 10000, error code 11022328
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
D2 Original Position Check
If this is set at less than -10000 or more than 10000, error code 11022329
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
PCB Check Position X, PCB Check Position Y
If either of these are at 0, error code 1102232D will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position X and Min Limit Position X Check
If either of these are at 0, error code 1102232E will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position Y and Min Limit Position Y Check
If either of these are at 0, error code 1102232F will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 32Version 2.0

Version 2.0
Chapter 5 Data Check ErrorsPart 6
Max Limit Position D1 and Min Limit Position D1 Check
If either of these are at 0, error code 11022339 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position D2 and Min Limit Position D2 Check
If either of these are at 0, error code 1102233A will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position Z and Min Limit Position Z Check
If either of these are at 0, error code 11022331 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
S Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022332 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
M Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022333 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
L Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022334 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 33