CP43操作手册.pdf.pdf - 第267页
Chapter 2 Details of Proper Data Part 4 76: HT Comment T erm. Code ASCII CODE # The Handy T erminal will disregar d the comments embedded in the selected ASCII code. The standard setting is “%.” 77: HT V erify T erm. Cod…

Chapter 2 Details of Proper DataPart 4
71: Verifier Tool Non: Barcode: Handy_term #
This sets the hardware used in device check.
Non: Handy Terminal not used
Barcode: Do not use this setting
Handy_term: Handy Terminal used
If “Barcode” is used, the device check may not work.The standard setting is
"Non."
72: Barcode Reader Type 0 ~ 9 #
This sets the type of bar code reader used in device check.
0: Not used
1: Do not use this setting
2: Epson HC-7 (Handy Terminal)
3 ~ 9: Same type of setting as 2.
If “1” is used the device check may not work. The standard setting is 0.
73: Device Check Port 0 ~ 30 #
If a Handy Terminal is used during device check, this sets the four channel
port number for the code reader.
0: Handy Terminal not used
1 ~ 30: Port number
The standard setting is 0.
74: ESC Permission Non: Permit #
This sets whether or not the [ESC] command can be used during device
check.
Non: [ESC] command cannot be used
Permit: [ESC] command can be used
The standard setting is "Permit."
75: MAN Permission Non: Permit #
This sets whether or not the machine can be controlled through the
numerical input keypad on the Handy Terminal.
Non: Keypad cannot be used
Permit: Keypad can be used
The standard setting is "Permit."
Version 5.0 4 – 28
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
76: HT Comment Term. Code ASCII CODE #
The Handy Terminal will disregard the comments embedded in the
selected ASCII code. The standard setting is “%.”
77: HT Verify Term. Code ASCII CODE #
The Handy Terminal will disregard any previous comments. The standard
setting is “/.”
78: D Change Trigger Error Parts Miss PD #
This sets the conditions under which device change (to the next device) is
carried out.
Error: Carried out if parts run out, if parts are mispicked or if there is a
vision processing error.
Parts: Carried out if parts run out.
Miss: Carried out if parts run out or if parts are mispicked.
PD : Carried out according to the conditions laid out in Part data.
The standard setting is "Error."
100:Pickup Position T1 -500000 ~ 0 [pulse] ✩❈
This sets the range of movement of the D1 axis from it's location when
zeroing is completed to the pickup position of device one.
This is a reference position for picking parts. If this value changes parts
will not be picked. A worst case scenario would involve damage to the
machine, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the D1 axis, one pulse is 0.0053 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 29Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
101:Pickup Position T2 0 ~ 500000 [pulse] ✩❈
This sets the range of movement of the D2 axis from it's location when
zeroing is completed to the pickup position of device 81.
This is a reference position for picking parts. If this value changes parts
will not be picked. A worst case scenario would involve damage to the
machine, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the D2 axis, one pulse is 0.0053 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
102:Origin Position Z -65000 ~ 65000 [pulse] ✩❈
This sets the range of movement of the Z axis from it's position above the
surface of the board when zeroing is complete to its lowest position 0.3 mm
above the board when the S nozzle on the A head is at station 7.
This reference value is set to match the height of parts with the height of
the XY table. If this value changes and parts are pressed into the board,
these parts could be destroyed, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the Z axis, one pulse is 0.002 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
103:Placing Position X -100000 ~ 0 [pulse] ✩❈
This sets the X coordinate for positioning the reference pin directly below
the S nozzle on the A head when this nozzle reaches station 7 after moving
from the X axis zeroing position.
This is the placing position reference value in the X direction. If this value
changes there can be no confidence in the accuracy of the X direction
placing position
When the motor is changed, this position must be measured again.
On the X axis, one pulse is 0.01 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 30
FCP IV-3 Operation