CP43操作手册.pdf.pdf - 第268页

Chapter 2 Details of Proper Data Part 4 101: Pickup Position T2 0 ~ 500000 [pulse] ✩❈ This sets the range of movement of the D2 axis from it's location when zeroing is completed to the pickup position of device 81. …

100%1 / 364
Chapter 2 Details of Proper DataPart 4
76: HT Comment Term. Code ASCII CODE #
The Handy Terminal will disregard the comments embedded in the
selected ASCII code. The standard setting is “%.”
77: HT Verify Term. Code ASCII CODE #
The Handy Terminal will disregard any previous comments. The standard
setting is “/.”
78: D Change Trigger Error Parts Miss PD #
This sets the conditions under which device change (to the next device) is
carried out.
Error: Carried out if parts run out, if parts are mispicked or if there is a
vision processing error.
Parts: Carried out if parts run out.
Miss: Carried out if parts run out or if parts are mispicked.
PD : Carried out according to the conditions laid out in Part data.
The standard setting is "Error."
100:Pickup Position T1 -500000 ~ 0 [pulse] ✩❈
This sets the range of movement of the D1 axis from it's location when
zeroing is completed to the pickup position of device one.
This is a reference position for picking parts. If this value changes parts
will not be picked. A worst case scenario would involve damage to the
machine, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the D1 axis, one pulse is 0.0053 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 29Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
101:Pickup Position T2 0 ~ 500000 [pulse] ✩❈
This sets the range of movement of the D2 axis from it's location when
zeroing is completed to the pickup position of device 81.
This is a reference position for picking parts. If this value changes parts
will not be picked. A worst case scenario would involve damage to the
machine, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the D2 axis, one pulse is 0.0053 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
102:Origin Position Z -65000 ~ 65000 [pulse] ✩❈
This sets the range of movement of the Z axis from it's position above the
surface of the board when zeroing is complete to its lowest position 0.3 mm
above the board when the S nozzle on the A head is at station 7.
This reference value is set to match the height of parts with the height of
the XY table. If this value changes and parts are pressed into the board,
these parts could be destroyed, so exercise extreme caution.
When the motor is changed, this position must be measured again.
On the Z axis, one pulse is 0.002 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
103:Placing Position X -100000 ~ 0 [pulse] ✩❈
This sets the X coordinate for positioning the reference pin directly below
the S nozzle on the A head when this nozzle reaches station 7 after moving
from the X axis zeroing position.
This is the placing position reference value in the X direction. If this value
changes there can be no confidence in the accuracy of the X direction
placing position
When the motor is changed, this position must be measured again.
On the X axis, one pulse is 0.01 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 30
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
104:Placing Position Y 0 ~ 100000 [pulse] ✩❈
This sets the.Y coordinate for positioning the reference pin directly below
the S nozzle on the A head when this nozzle reaches station 7 after moving
from the Y axis zeroing position.
This is the placing position reference value in the Y direction. If this value
changes there can be no confidence in the accuracy of the Y direction
placing position
When the motor is changed, this position must be measured again.
On the Y axis, one pulse is 0.01 mm.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
105:Loading Position X -100000 ~ 0 [pulse] ✩❈
This is the X coordinate for board loading and unloading.
This sets the range of movement in the X direction from the position of the
X axis when zeroing is completed to the board loading position.
This reference value determines the position on the X axis from which the
board is loaded. If this value changes the board will not be loaded and
unloaded properly. A worst case scenario would mean an accident
involving a total breakdown in board transport accuracy, so exercise
extreme caution.
When the motor is changed, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 31Version 5.0
FCP IV-3 Operation