CP43操作手册.pdf.pdf - 第277页
Chapter 2 Details of Proper Data Part 4 143: Rough Pulse D2 0 ~ 65535 [pulse] ✩❈ This roughly aligns the D2 axis servos. If this value is changed the machine will not operate normally , so exercise extreme caution. The s…

Chapter 2 Details of Proper DataPart 4
135:Skip Nozzle S: 0 ~ 12 #
This sets a limit on the number of S nozzles which can be skipped. The
standard setting is 3.
136:Skip Nozzle M: 0 ~ 12 #
This sets a limit on the number of M nozzles which can be skipped. The
standard setting is 3.
137:Skip Nozzle L: 0 ~ 12 #
This sets a limit on the number of L nozzles which can be skipped.The
standard setting is 3.
138:M/C Size 4000: 5000 $
This setting indicates the physical size of the machine.
4000: 4000 type
5000: 5000 type
The standard setting is 4000.
139:D ESC sw No : Yes #
This designates the position to which the device table will move for
supplying parts.
If set to "Yes" the device table will move to its resupply position when parts
run out. If set to "No" the device table will move to a position 18 device
positions away from the part pickup point. The device table stops at this
position to wait for parts to be resupplied. The standard setting is "No."
140:Rough Pulse X 0 ~ 65535 [pulse] ✩❈
This roughly aligns the X axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
141:Rough Pulse Y 0 ~ 65535 [pulse] ✩❈
This roughly aligns the Y axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
142:Rough Pulse D1 0 ~ 65535 [pulse] ✩❈
This roughly aligns the D1 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 30.
Version 5.0 4 – 38
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
143:Rough Pulse D2 0 ~ 65535 [pulse] ✩❈
This roughly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 30.
144:Rough Pulse C 0 ~ 65535 [pulse] ✩❈
This roughly aligns the C axis servos. The standard setting is 10.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
145:Rough Pulse FQ 0 ~ 65535 [pulse] ✩❈
This roughly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
146:Rough Pulse Z 0 ~ 65535 [pulse] ✩❈
This roughly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 100.
147:Reach Pulse X 0 ~ 65535 [pulse] ✩❈
This exactly aligns the X axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
148:Reach Pulse Y 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Y axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
149:Reach Pulse D1 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D1 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
150:Reach Pulse D2 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
4 – 39Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
151:Reach Pulse C 0 ~ 65535 [pulse] ✩❈
This exactly aligns the C axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
152:Reach Pulse FQ 0 ~ 65535 [pulse] ✩❈
This exactly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
153:Reach Pulse Z 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
160:SA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
⇓
171:SL Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the S nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
172:MA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
⇓
183:ML Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the M nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 40
FCP IV-3 Operation