CP43操作手册.pdf.pdf - 第272页

Chapter 2 Details of Proper Data Part 4 1 13: Max Limit Position X 0 ~ 100000 [pulse] ✩❈ This is the maximum limit coordinate of the X axis in the + dir ection. If the X axis overtravel sensor goes ON due to the servo co…

100%1 / 364
Chapter 2 Details of Proper DataPart 4
109:PCB Check Position X -100000 ~ 100000 [pulse] ✩❈
This is the position of the board check sensor, which checks to see that the
board has been properly clamped.
This sets the range of movement of the X axis between it's location when
zeroing is completed and the location of the board check sensor.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
110:PCB Check Position Y 0 ~ 100000 [pulse] ✩❈
This is the position of the board check sensor, which checks to see that the
board has been properly clamped.
This sets the range of movement of the Y axis between it's location when
zeroing is completed and the location of the board check sensor.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
111:D1 Original Position -10000 ~ 10000 [pulse] ✩❈
This sets the distance from the zero position of the D1 axis to the resupply
position of device table 1.
Do not change these values as they could result in the machine being
damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
112:D2 Original Position -10000 ~ 10000 [pulse] ✩❈
This sets the distance from the zero position of the D2 axis to the resupply
position of device table 2.
Do not change these values as they could result in the machine being
damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 33Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
113:Max Limit Position X 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the X axis in the + direction.
If the X axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the X axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
114:Max Limit Position Y 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the Y axis in the + direction.
If the Y axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Y axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
115:Max Limit Position D1 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the D1 axis in the + direction.
If the D axis overtravel sensor goes ON due to the servo count then set the
value back 25 pulses.
If the D1 axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 34
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
116:Max Limit Position D2 -10000 ~ 500000 [pulse] ✩❈
This is the maximum limit coordinate of the D2 axis in the + direction.
If the D2 axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the D2 axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
117:Max Limit Position Z -65000 ~ 65000 [pulse] ✩❈
This is the maximum limit coordinate of the Z axis in the + direction.
If the Z axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Z axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
118:Min Limit Position X -10000 ~ 0 [pulse] ✩❈
This is the minimum limit coordinate of the X axis in the - direction.
If the X axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the X axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 35Version 5.0
FCP IV-3 Operation