CP43操作手册.pdf.pdf - 第216页
FCP IV -3 Operation • Function Key Menu Chapter 3 Description of Commands Setting Narrow V iew Camera Brightness Part 3 3 – 91 NARROW Page 531 530 ▲ ■ ▼ SELECT RETURN V ersion 5.0 • Action of the Function Keys ▲ : Press …

FCP IV-3 Operation
• Function Key Menu
Chapter 3 Description of Commands
Setting Wide View Camera
Brightness
Part 3
3 – 90
WIDE
Page
531 520
▲ ■ ▼
SELECT RETURN
Version 5.0
• Action of the Function Keys
▲ : Press to change the gain or offset level by +1.
■ : Press with ▲ or ▼ to change the gain or offset
level in increments of 10.
▼ : Press to change the gain or offset level by -1.
SELECT : Press to switch between the type of setting
(i.e.gain or offset).
RETURN : Press this button to return to page 531/500.
The gain and offset levels set here are machine Proper data
settings and thus it is necessary to transmit Proper data to the
MCS 30 computer once Proper data measurement is
completed.
Note: The desired level can be set either by entering a number using
the numerical keypad, or by using the function keys.
• First Display Area
Parts Camera
[WIDE VIEW]
Gain 10
Offset 0
To Page 531/500

FCP IV-3 Operation
• Function Key Menu
Chapter 3 Description of Commands
Setting Narrow View Camera
Brightness
Part 3
3 – 91
NARROW
Page
531 530
▲ ■ ▼
SELECT RETURN
Version 5.0
• Action of the Function Keys
▲ :Press to change the gain or offset level by +1.
■ :Press with ▲ or ▼ to change the gain or offset
level in increments of 10.
▼ :Press to change the gain or offset level by -1.
SELECT :Press to switch between the type of setting
(i.e.gain or offset).
RETURN :Press to return to Page 531/500.
The gain and offset levels set here are machine Proper data
settings and thus it is necessary to transmit Proper data to the
MCS 30 computer once Proper data measurement is
completed.
Note : The desired level can be set either by entering a number using
the numerical keypad, or by using the function keys.
• First Display Area
Parts Camera
[NARROW VIEW]
GAIN LEVEL 12
OFFSET LEVEL 0
To Page 531/500

• Action of the Function Keys
X0/Y0 :Press to set the measurement results of the
reference point into Proper data.
XL/YL :Press to set the loading position
measurement results into Proper data.
XPCB/YPCB :Press to set the measurement results of board
check position into Proper data.
XMAX/YMAX :Press to set the measurement results of the
maximum movable area into Proper data.
XMIN/YMIN :Press to set the measurement results of the
mininum movable area into Proper data.
RETURN :Press to return to Page 530/000.
• First Status Area
X/Y
• First Display Area
Proper Data
Placing Pos. X0 : -49365 Mode : 1
Y0 : 32989 Servo counter
Loading Pos. XL : 170 X -049365
YL : -320 Y 0032989
PCB Check Pos. XPCB : 21 C 000000
XPCB : 23 D1 -482476
Max Limit Pos. Xmax : -6900 D2 -000001
Ymax : 340 Z -000390
Min Limit Pos. Xmin : 127 FQ 0005170
Ymin : 58 World (Zero)
• Function Key Menu
Chapter 3 Description of Commands
To Page 532/100
To Page 532/100
To Page 532/100
To Page 532/100
To Page 532/100
To Page 530/000
Measuring Proper Data for
X, Y Axis
Part 3
3 – 92
X/Y
Page
532 000
X0/Y0 XL/YL XPCB/YPCB XMAX/YMAX XMIN/YMIN RETURN
Version 5.0
FCP IV-3 Operation