CP43操作手册.pdf.pdf - 第262页

Chapter 2 Details of Proper Data Part 4 25: Conveyor Control Manu: Auto $ # This is valid only for HELPS-compatible machines. This selects whether or not the conveyor width will be controlled automatically . Manu: Manual…

100%1 / 364
Chapter 2 Details of Proper DataPart 4
13: Machine_ID 0000 0000 0000 0000
This is one of the machine’s special operating parameters (input as a 16 bit
binary mask pattern). The standard setting is 0000 0000 0000 0000.
14: PCB_Location Corner: Pin $
This sets the method used to locate the board on the XY table.
Corner: Corner used as standard
Pin: Reference pin used as standard
The standard setting is "Corner."
15: Reserve 1 Not used at present $
16: Reserve 2 Not used at present $
17: Reserve 3 Not used at present $
18: Reserve 4 Not used at present $
19: Reserve 5 Not used at present $
20: Loader Status A 0000 0000 0000 0000 $
This sets board loader operating conditions (input as a 16 bit binary mask
pattern). The standard setting is 0000 0000 0000 0000.
21: Loader Status A 0000 0000 0000 0000 $
This sets board loader operating conditions (input as a 16 bit binary mask
pattern). The standard setting is 0000 0000 0000 0000.
22: Conveyor Type L]R: R]L$
This sets the direction of the conveyor board.
L->R: Left to right
R->L: Right to left (Optional)
The standard setting is L]R.
23: Wait Signal Off: On $
This chooses whether or not the wait signal works.
The standard setting is "Off."
24: Busy Invalid No: Yes $#
Sets whether or not machine refers to board request signals from the
previous stage.
No: Ignore board request signals and feed out boards when they become
available.
Yes: Refer to board request signals
The standard setting is "No."
4 – 23Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
25: Conveyor Control Manu: Auto $#
This is valid only for HELPS-compatible machines. This selects whether or
not the conveyor width will be controlled automatically.
Manu: Manual conveyor adjustment
Auto: Automatic conveyor adjustment
The standard setting is "Manu."
26: Conveyor Adj. Limit 0.05 ~ 1.00 [mm] $#
This is valid only for HELPS-compatible machines. This sets the limit to
determine if fine adjustment of the conveyor width is required. Fine
adjustment is carried out if the difference between the current conveyor
width and the board width set in the program exceeds this limit. The
standard setting is 0.50 mm.
27: Conveyor Stop Offset 0.00 ~ 2.00 [mm] $#
This is valid only for HELPS-compatible machines. This sets the conveyor
stop offset during conveyor width adjustment. The standard setting is 0.30
mm.
28: Conveyor adj. Timer 0 ~ 120000 [msec] $#
This is valid only for HELPS-compatible machines. When performing
automatic conveyor width adjustment this value sets the amount of time
that elapses before a time-up error occurs. The standard setting is 60000
msec.
29: Width Max Limit 0.00 ~ 655.35 [mm] $
This sets the maximum conveyor width value. The standard setting is
460.00 mm.
30: Width Min Limit 0.00 ~ 655.35 [mm] $
This sets the minimum conveyor width value. The standard setting is
050.00 mm.
40: LMS Flag Off: On $#
This sets whether the unit will be used as a normal or HELPS compatible
machine.
Off: Not compatible
On: Compatible
The standard setting is "Off."
Version 5.0 4 – 24
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
41: Cell Status Unit: Active: Passive $#
This is valid only for HELPS-compatible machines. This sets cell status.
Unit: Unit cell
Active: Active cell
Passive: Passive cell
The standard setting is "Unit."
42: Change Over Mode 0 ~ 200 $#
This is valid only for HELPS-compatible machines. The standard setting
is 0.
43: Auto Start No: Yes $#
This is valid only for HELPS-compatible machines. It sets the start-up
method after changeover has finished.
No: Machine waits for [START] button to be pressed after changeover
is finished.
Yes: Automatic start.
The standard setting is "No."
44: Backup Plate Check No: Yes $#
On HELPS-compatible machines, this determines whether a backup plate
check will be done during changeover.
No: No backup plate changeover check.
Yes: Backup plate changeover check.
The standard setting is "No."
45: Command Line Status RS232C: LAN $
This sets the mode of transmission with LMS.
RS232C: Use RS232C
LAN: Use LAN
ETHERNET: Use Ethernet
The standard setting is "RS232C."
46: Command Line Port 0 ~ 30 $#
On HELPS-compatible machines, use the command line to set the RS232C
ports that will be used.
0: Command line will not be used.
1 - 8: Port numbers.
The standard setting is 0.
4 – 25Version 5.0
FCP IV-3 Operation