Chapter 1 Errors and Countermeasures Part 6 Parts not set Cause: In device change mode the parts have not been set on the next device table. Remedy: Set the parts. Max D No. Error Cause: In device change mode or in chang…

100%1 / 364
Chapter 1 Errors and CountermeasuresPart 6
1.3 Alarms Which Prevent the Machine from Being Started
When it is not possible to start the machine, the cause of this will be
displayed. Once the cause has been removed the "Press START" message
will automatically appear.
Cam Handle Alarm
Cause: The cam handle cannot be detected.
Remedy: Return the cam handle back to its original position.
Vacuum Alarm
Cause: The vacuum pressure has fallen below the standard level.
Remedy: Close the mechanical valves at each station and check the
vacuum pump.
Air Pressure Alarm
Cause: The air pressure has fallen below the standard level.
Remedy: Check the air supply.
Safety Door, Front
Safety Door, Rear
Safety Door 1
Safety Door 2
Cause: Either the front door is open or one of the sensors at the rear of
the machine has been triggered.
Remedy: Close the door or remove the offending object.
Return Cam to Zero
Cause: The input of the cam axis zero position sensor cannot be
recognized.
Remedy: Return the cam axis to it's zero position either by using the cam
handle or by inching.
Lifter Not at Lower Limit
Cause: The lifter is not at it's lowered position.
Remedy: Lower the lifter.
6 – 8Version 2.0
Chapter 1 Errors and CountermeasuresPart 6
Parts not set
Cause: In device change mode the parts have not been set on the next
device table.
Remedy: Set the parts.
Max D No. Error
Cause: In device change mode or in changeover mode the production
program calls for a device number greater than 80.
Remedy: Change the program so that it only calls for device numbers less
than 81.
No Production Program
Cause: A valid program has not been transmitted to the machine or a
program has not been chosen.
Remedy: Transmit a valid program to the machine or choose a program.
No Proper
Cause: Valid Proper data has not been transmitted to the machine.
Remedy: Transmit valid Proper data to the machine.
No Status
Cause: Valid Status data has not been transmitted to the machine.
Remedy: Transmit valid Status data to the machine.
GD Train Error
Cause: A device description download error was detected.
Remedy: Correct and re-transmit the program which produced the error.
6 – 9Version 2.0
Chapter 1 Errors and CountermeasuresPart 6
1.4 Alarms Which Prevent [RETURN] and Shut-down
Vision System Alarm
Cause: The vision processing system is hung.
Remedy: Reboot the machine. If it appears to reboot normally, survey the
situation before proceeding. If it does not reboot normally, and the alarm
occurs again, the vision processing board is probably defective.
6 – 10Version 2.0