Chapter 2 Details of Proper Data Part 4 1 16: Max Limit Position D2 -10000 ~ 500000 [pulse] ✩❈ This is the maximum limit coordinate of the D2 axis in the + dir ection. If the D2 axis overtravel sensor goes ON due to the …

Chapter 2 Details of Proper DataPart 4
113:Max Limit Position X 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the X axis in the + direction.
If the X axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the X axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
114:Max Limit Position Y 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the Y axis in the + direction.
If the Y axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Y axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
115:Max Limit Position D1 0 ~ 100000 [pulse] ✩❈
This is the maximum limit coordinate of the D1 axis in the + direction.
If the D axis overtravel sensor goes ON due to the servo count then set the
value back 25 pulses.
If the D1 axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 34
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
116:Max Limit Position D2 -10000 ~ 500000 [pulse] ✩❈
This is the maximum limit coordinate of the D2 axis in the + direction.
If the D2 axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the D2 axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
117:Max Limit Position Z -65000 ~ 65000 [pulse] ✩❈
This is the maximum limit coordinate of the Z axis in the + direction.
If the Z axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Z axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
118:Min Limit Position X -10000 ~ 0 [pulse] ✩❈
This is the minimum limit coordinate of the X axis in the - direction.
If the X axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the X axis exceeds the set coordinate, an alarm will go off and the
machine will stop.
Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 35Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
119:Min Limit Position Y -10000 ~ 0 [pulse] ✩❈
This is the minimum limit coordinate of the Y axis in the - direction.
If the Y axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Y axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
120:Min Limit Position D1 -500000 ~ 10000 [pulse] ✩❈
This is the minimum limit coordinate of the D1 axis in the - direction.
If the D1 axis overtravel sensor goes ON due to the servo count then set the
value back 25 pulses.
If the D1 axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
121:Min Limit Position D2 -500000 ~ 10000 [pulse] ✩❈
This is the minimum limit coordinate of the D2 axis in the - direction.
If the D2 axis overtravel sensor goes ON due to the servo count then set the
value back 25 pulses.
If the D2 axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 36
FCP IV-3 Operation