V ersion 2.0 Chapter 5 Data Check Errors Part 6 Max Limit Position D1 and Min Limit Position D1 Check If either of these are at 0, err or code 1 1022339 will appear . Remedy: Carry out Pr oper data measurement and then t…

100%1 / 364
Chapter 5 Data Check ErrorsPart 6
Pickup Position D2 Check
If this is set at less than 100000 or more than 300000, error code 1102233B
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
D1 Original Position Check
If this is set at less than -10000 or more than 10000, error code 11022328
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
D2 Original Position Check
If this is set at less than -10000 or more than 10000, error code 11022329
will result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
PCB Check Position X, PCB Check Position Y
If either of these are at 0, error code 1102232D will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position X and Min Limit Position X Check
If either of these are at 0, error code 1102232E will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position Y and Min Limit Position Y Check
If either of these are at 0, error code 1102232F will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 32Version 2.0
Version 2.0
Chapter 5 Data Check ErrorsPart 6
Max Limit Position D1 and Min Limit Position D1 Check
If either of these are at 0, error code 11022339 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position D2 and Min Limit Position D2 Check
If either of these are at 0, error code 1102233A will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
Max Limit Position Z and Min Limit Position Z Check
If either of these are at 0, error code 11022331 will appear.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
S Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022332 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
M Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022333 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
L Nozzle Place Offset X Check
If this is set at less than -2000 or more than 2000, error code 11022334 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 33
Chapter 5 Data Check Errors
Part 6
S Nozzle Place Offset Y Check
If this is set at less than -2000 or more than 2000, error code 11022332 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
M Nozzle Place Offset Y Check
If this is set at less than -2000 or more than 2000, error code 11022333 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
L Nozzle Place Offset Y Check
If this is set at less than -2000 or more than 2000, error code 11022334 will
result.
Remedy: Carry out Proper data measurement and then transmit the
corrected Proper data.
6 – 34Version 2.0