• Action of the Function Keys D1 MIN : Pr ess to set the D1 min calibration results in Proper data. D2 MIN : Pr ess to set the D2 min calibration results in Proper data. Z MIN : Press to set the Z min calibration results…

100%1 / 364
Action of the Function Keys
D1 MAX :Press to set the D1 max calibration results in
Proper data.
D2 MAX :Press to set the D2 max calibration results in
Proper data.
Z MAX :Press to set the Z max calibration results in
Proper data.
Note: Pressing either of the above commands will display "SET."
Press [SET] to set the Proper data.
RETURN :Press to return to Page 533/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on setting Proper data refer to the FCP IV-3 Maintenance
Manual.
Function Key Menu
Chapter 3 Description of Commands
Setting D, Z Axis
Positive Stroke
Part 3
3 – 98
MAX LIMIT
Page
533 300
D1 MAX D2 MAX Z MAX RETURN
Version 5.0
FCP IV-3 Operation
To Page 533/110
To Page 533/110
To Page 533/110
To Page 533/000
Action of the Function Keys
D1 MIN :Press to set the D1 min calibration results in
Proper data.
D2 MIN :Press to set the D2 min calibration results in
Proper data.
Z MIN :Press to set the Z min calibration results in
Proper data.
Note: Pressing either of the above commands will display "SET."
Press [SET] to set the Proper data.
RETURN :Press to return to Page 533/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on setting Proper data refer to the FCP IV-3 Maintenance
Manual.
Function Key Menu
Chapter 3 Description of Commands
To Page 533/110
To Page 533/110
To Page 533/110
To Page 533/000
Setting D, Z Axis
Negative Stroke
Part 3
3 – 99
MIN LIMIT
Page
533 400
D 1 MIN D 2 MIN Z MIN RETURN
Version 5.0
FCP IV-3 Operation
Action of the Function Keys
SPEED :Press to change the inching speed.
CONV WIDTH : Press to set or change the conveyor
width. This function key is effective
only when the machine is set to
automatically adjust conveyor width.
TRACE LIST :Press to display the servo board
conditions. This command is for
debug use.
MODE :Press to change the servo counter
display mode.
"World (Zero)" is displayed. On the
world coordinate system zero is defined
as the position of every axis after zero
setting has finished.
"World (Prog)" is displayed. On the
world coordinate system, the pulse
positions are recorded at the placing
position in the X and Y axes, at the origin
position in the Z axis and at device
position number one in the D axis.
"Pulse (Zero)" is displayed. For the servo
axes the monitor will display the number
of pulses after zero setting.
"Pulse (Prog)" is displayed. On the servo
axes, the pulse positions are recorded at
the parts placing position in the X and Y
axes, at the origin position in the Z axis
and at device position one in the D axis.
RETURN :Press to return to Page 500/000.
Function Key Menu
Chapter 3 Description of Commands
To Page 541/000
To Page 542/000
To Page SRV
To Page 500/000
Making Servo-Related Settings
Part 3
3 – 100
SERVO
Page
540 000
SPEED CONV WIDTH TRACE LIST MODE RETURN
Version 5.0
FCP IV-3 Operation