CP43操作手册.pdf.pdf - 第74页
Chapter 1 Automatic Operation Part 2 If a nozzle of the same diameter as Nozzle_size_CP4 does not exist in Machine_data, an error will occur when the pr ogram is transmitted. In this case the error 1 101 108 ? will be ge…

Chapter 1 Automatic OperationPart 2
If there is no value larger than the smallest permissible reflective
disk value input in Proper data, vision processing cannot be carried
out properly and an error will result.
If all the values in the program's Machine_data are smaller than the
smallest permissible reflective disk value input in Proper data, the
machine will judge this nozzle to be unusable and the error code
1101D04 will occur while the program is being transmitted.
1.1.6 Forcing a Specific Nozzle
If a part must be placed with a nozzle of a specific diameter, input
the nozzle diameter in Carrying_data's Nozzle_size_CP4 item. The
nozzle in the program that matches this input will be selected.
Nozzle_size_max will be ignored in this case.
For example, if data is input as shown below, the S nozzle will be
selected since it matches the size specified under Nozzle_size_CP4.
Program
Machine_data
38. S_nozzle_size : 1.0
39. M_nozzle_size : 1.3
40. L_nozzle_size : 2.5
42. S_back_light_size:12
43. M_back_light_size:12
44. S_back_light_size:25
Device_data
D1 RECT3216120
D2 RECT2125C
Part data
D1 RECT3216120
16. Back_light_min :12
17. Nozzle_size_max : 1.3
19. Nozzle_size_CP4 : 1.0
Program
Machine_data
38. S_nozzle_size : 0.7
39. M_nozzle_size : 1.0
40. L_nozzle_size : 2.5
42. S_back_light_size:12
43. M_back_light_size:12
44. S_back_light_size:25
Device_data
D1 RECT3216120
D2 RECT2125C
Part data
D1 RECT3216120
16. Back_light_min :30
17. Nozzle_size_max : 1.3
19. Nozzle_size_CP4 : 0
2 – 5Version 2.0
FCP IV-3 Operation

Chapter 1 Automatic OperationPart 2
If a nozzle of the same diameter as Nozzle_size_CP4 does not exist
in Machine_data, an error will occur when the program is
transmitted.
In this case the error 1101108? will be generated, where ? is the
device number divided by 13 and truncated.
As with automatic selection, if there is no value larger than the
smallest permissible reflective disk value input in Proper data,
vision processing cannot be carried out properly and an error will
result.
If all the values in the program's Machine_data are smaller than the
smallest permissible reflective disk value input in Proper data, the
machine will judge this nozzle to be unusable and the error code
1101D04 will occur while the program is being transmitted.
Program
Machine_data
38. S_nozzle_size : 1.0
39. M_nozzle_size : 1.3
40. L_nozzle_size : 2.5
42. S_back_light_size:12
43. M_back_light_size:12
44. S_back_light_size:25
Device_data
D1 RECT3216120
D2 RECT2125C
Part data
D1 RECT3216120
16. Back_light_min :30
17. Nozzle_size_max : 1.3
19. Nozzle_size_CP4 : 1.0
Program
Machine_data
38. S_nozzle_size : 0.7
39. M_nozzle_size : 1.3
40. L_nozzle_size : 2.5
42. S_back_light_size:12
43. M_back_light_size:12
44. S_back_light_size:25
Device_data
D1 RECT3216120
D2 RECT2125C
Part data
D1 RECT3216120
16. Back_light_min :12
17. Nozzle_size_max : 1.3
19. Nozzle_size_CP4 : 1.0
2 – 6Version 2.0
FCP IV-3 Operation

Chapter 1 Automatic OperationPart 2
1.1.7 Nozzle Check Function
This function checks the production program to confirm that the
appropriate nozzle is installed in each holder. This is done by
performing a check on the nozzle diameter and the background
disk diameter.
If a program has been transmitted to the foreground, then once
program changeover has been completed.the Nozzle Check
function is carried out when automatic operation begins. However,
if the nozzles installed in the previous production program have
the same nozzle diameter and background disk diameter as the
nozzles set to be used in the current production program then no
check is performed. If either the nozzle diameter or the
background disk diameter are different then a check is performed.
It is necessary to set Proper data for this function to work. Make
the setting in the following manner:
Proper
124. Nozzle Check SW: This Proper data function sets
whether or not the function will be
performed. Set it to YES or NO.
When the Nozzle Check function is operative a display like the one
below will appear.
SET: Press this key to set the selected nozzle.
▲: Press this key to move the cursor up.
▼: Press this key to move the cursor down.
RETURN: Press this key to return the display to page 000/000.
"UNSET" is displayed in red and "SET" is displayed in green.
SET ▼ RETURN
HOLDER Noz.Diam. LUMI.DIAM
S Holder 0.70mm 12mm UNSET
M Holder 1.30mm 12mm SET
L Holder 2.50mm 25mm UNSET
Press [SET] to Define Nozzle Diameter
Ready
▲
2 – 7Version 2.0
FCP IV-3 Operation