CP43操作手册.pdf.pdf - 第276页
Chapter 2 Details of Proper Data Part 4 135: Skip Nozzle S: 0 ~ 12 # This sets a limit on the number of S nozzles which can be skipped. The standard setting is 3. 136: Skip Nozzle M: 0 ~ 12 # This sets a limit on the num…

Chapter 2 Details of Proper DataPart 4
122:Min Limit Position Z -65000 ~ 65000 [pulse] ✩❈
This is the minimum limit coordinate of the Z axis in the - direction.
If the Z axis overtravel sensor goes ON due to the servo count then set the
value back 100 pulses.
If the Z axis exceeds the set coordinate, an alarm will cause the machine to
stop. Do not change this setting, as the machine could be damaged.
When the motor is replaced, this position must be measured again.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
130:Nozzle Check SW No: Yes #
This sets whether or not there will be a mandatory nozzle check when the
machine enters automatic operation.
No: No mandatory nozzle check
Yes: Mandatory nozzle check
The standard setting is "Yes."
131:Narrow Camera Non: Use ❈
This sets whether or not a camera with a narrow field of vision will be
used.
Non: Not used
Use: Used
This Proper data item is not currently in use on the FCP-IV. The standard
setting is "Yes."
132:Front Light Non: Use ❈
This is set depending on whether or not the optional front light system is
operational.
Non: Not in use
Use: In use
The standard setting is "Non."
133:Cam Speed 0 ~ 100.0 [0.1%] #
This sets the speed of the cam axis in percentage terms (units of 0.1%). The
standard setting is 100.0.
134:Skip Number 0 ~ 16 #
This sets the number of nozzle errors (for a specific nozzle) tolerated before
that nozzle is skipped. The standard setting is 0.
4 – 37Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
135:Skip Nozzle S: 0 ~ 12 #
This sets a limit on the number of S nozzles which can be skipped. The
standard setting is 3.
136:Skip Nozzle M: 0 ~ 12 #
This sets a limit on the number of M nozzles which can be skipped. The
standard setting is 3.
137:Skip Nozzle L: 0 ~ 12 #
This sets a limit on the number of L nozzles which can be skipped.The
standard setting is 3.
138:M/C Size 4000: 5000 $
This setting indicates the physical size of the machine.
4000: 4000 type
5000: 5000 type
The standard setting is 4000.
139:D ESC sw No : Yes #
This designates the position to which the device table will move for
supplying parts.
If set to "Yes" the device table will move to its resupply position when parts
run out. If set to "No" the device table will move to a position 18 device
positions away from the part pickup point. The device table stops at this
position to wait for parts to be resupplied. The standard setting is "No."
140:Rough Pulse X 0 ~ 65535 [pulse] ✩❈
This roughly aligns the X axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
141:Rough Pulse Y 0 ~ 65535 [pulse] ✩❈
This roughly aligns the Y axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
142:Rough Pulse D1 0 ~ 65535 [pulse] ✩❈
This roughly aligns the D1 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 30.
Version 5.0 4 – 38
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
143:Rough Pulse D2 0 ~ 65535 [pulse] ✩❈
This roughly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 30.
144:Rough Pulse C 0 ~ 65535 [pulse] ✩❈
This roughly aligns the C axis servos. The standard setting is 10.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
145:Rough Pulse FQ 0 ~ 65535 [pulse] ✩❈
This roughly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
146:Rough Pulse Z 0 ~ 65535 [pulse] ✩❈
This roughly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 100.
147:Reach Pulse X 0 ~ 65535 [pulse] ✩❈
This exactly aligns the X axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
148:Reach Pulse Y 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Y axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
149:Reach Pulse D1 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D1 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
150:Reach Pulse D2 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
4 – 39Version 5.0
FCP IV-3 Operation