Service Work 3.6.22 Replacing the Conversion Board [03081718-xx] Conveyor Service Manual SIPLACE SX4/DX4 131 3.6.22 3 . 6 . 2 2 R e p la c in g t h e C o n v e r s io n B o a r d [ 0 3 0 8 1 7 1 8 - x x ] Replacing the C…

Service Work
Conveyor 3.6.21 Replacing the Ultrasonic Sensor PXS240 [03069863-xx]
130 Service Manual SIPLACE SX4/DX4
Assembly Differences on the Conversion Board
► Observe the following differences during assembly on the conversion board at the end of PA1 and
at the beginning of PA2:
Functional check
► Perform a function check. If this is not successful, you will need to reteach the sonar sensor. (see
"5.5.2 Teaching the Sonar Sensor PXS240" [ ➙ 256]).
See also
3.6.1 Loosening the Conveyor Side Clamps [ ➙ 95]
1. Assembly of old sonar sensor [03069863-xx]
2. Assembly of new sonar sensor [03089004-xx]
The old sonar sensor is fixed separately behind the con-
version board.
A Diagram with conversion board B Diagram with conversion board hidden
1 Screw M4x16mm
DIN-EN-ISO7380-M3x16-A2-70
[03040340-xx]
2 Nut as spacer
ISO4032-M4-A2-70 [03008166-xx]
3 Screw M4x20mm
DIN-EN-ISO7380-M3x20-A2-70
[03045197-xx]
4 Spacer bolt

Service Work
3.6.22 Replacing the Conversion Board [03081718-xx] Conveyor
Service Manual SIPLACE SX4/DX4 131
3.6.22
3.6.22 Replacing the Conversion Board [03081718-xx]
Replacing the Conversion Board [03081718-xx]
Parts, equipment and tools
▪ Conversion board assembly [03081718-xx]
Overview
Removal
► Use the software to move the conveyor sides into the position which allows you best access. As an
alternative, you can loosen the clamps for the relevant sides in dual conveyors.
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Dismantle the cover plate on the sensor rail.
► Unplug all connections to the conversion board. You may want to mark the positions, to make clear
assignment easier later on.
► Loosen the screws fastening the conversion board and remove it from the machine.
Installation
► Follow the removal instructions in reverse order for installation.
See also
3.6.1 Loosening the Conveyor Side Clamps [ ➙ 95]
1. Conversion board
2. Ultrasonic sensors (3x)
3. Solenoid valves (2x)
4. Stoppers (2x)
► If needed, the sensor rail can be removed to allow
better access. Simply loosen the two screws (1) on
the ends of both shafts.

Service Work
Conveyor 3.6.23 Replacing the Clamping Plate [03081665-xx]
132 Service Manual SIPLACE SX4/DX4
3.6.23
3.6.23 Replacing the Clamping Plate [03081665-xx]
Replacing the Clamping Plate [03081665-xx]
Parts, equipment and tools
▪ Clamping plate assembly [03081665-xx]
▪ Tool for travel limitation [03013650-xx]
Overview
Removal
► Use the software to move the conveyor sides into the position which allows you best access. As an
alternative, you can loosen the clamps for the relevant sides in dual conveyors.
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
See also
3.6.1 Loosening the Conveyor Side Clamps [ ➙ 95]
3.6.24
3.6.24 Replacing the Compression Spring on the Clamping Plate [00364715-xx]
Replacing the Compression Spring on the Clamping Plate [00364715-xx]
Parts, equipment and tools
▪ Compression spring 0.63*5.63*26 [00364715-xx]
▪ Tool for travel limitation [03013650-xx]
Removal/installation
► Removal and installation of the pressure spring is the same as that for the clamping plate. (See
"3.6.23 Replacing the Clamping Plate [03081665-xx]" [ ➙ 132])
Clamping plate (using example of SX1/SX2)
1. Screws fastening the clamping plate
2. Clamping plate
Clamping plate (using example of SX1/SX2)
► Loosen the 6 screws fastening the clamping plate
and remove the clamping plate. Make sure that you
do not lose the two compression springs (1).
CAUTION
Installation instructions
► Reinsert the compression springs.
► Check the clamping plate for ease of movement.