SIPLACE-SX4-DX4-用户手册.pdf - 第82页

Service Work Gantries 3.5.5 Replacing the Trailing Cable 82 Service Manual SIPLACE SX4/DX4 Removal ► Disconnect the cooling tubes (4) from the Y motor. ► Loosen the flat ribbon cable on the trailing cable interface ga nt…

100%1 / 298
Service Work
3.5.5 Replacing the Trailing Cable Gantries
Service Manual SIPLACE SX4/DX4 81
Overview
See also
3.5.5.2.3 Preparing the Trailing Cable [ ➙ 79]
3.5.5.1.1 Handling the Hose Unlocking Tool [03047090-xx] [ ➙ 78]
1. Vision board spread spectrum (VBSX) assembly
[03067289-xx]
This board is located at the top of the head interface.
2. Trailing cable console
3. Power track chain
4. Trailing interface for gantry
Gantry 2 and 4 [03071356-xx]
Gantry 1 and 3 [03071355-xx]
5. Pneumatic hoses to the pneumatic distributor (in the
machine base)
6. Gantry interface
Gantry 2 and 4 [03059909-xx]
Gantry 1 and 3 [03059908-xx]
7. Connection piece for cooling tubes to Y motor
8. Vision hotlink adapter VHA [03050555-xx]
9. MODULE/Head interface
C700X-L [03055068-xx]
C700X-R [03055070-xx]
10. Pneumatic distributor
Service Work
Gantries 3.5.5 Replacing the Trailing Cable
82 Service Manual SIPLACE SX4/DX4
Removal
Disconnect the cooling tubes (4) from the Y motor.
Loosen the flat ribbon cable on the trailing cable interface gantry (1). Take care not to lose the brack-
ets for the press-fit connections. They could fall out and be lost.
Remove cable ties where necessary.
Remove the necessary cable ties at the gantry interface (4) and disconnect the flat ribbon cable.
Disconnect the motor, proximity switches, incremental encoder and temperature sensor cables from
the gantry interface (4).
1. Trailing interface for gantry
Gantry 2 and 4 [03071356-xx]
Gantry 1 and 3 [03071355-xx]
2. Gantry interface
Gantry 2 and 4 [03059909-xx]
Gantry 1 and 3 [03059908-xx]
3. Mount for trailing cable
4. Cooling tubes
CAUTION
Note the order in which the terminal connections are arranged.
Label the press-fit connections to the flat ribbon cables, for easier reconnection later.
NOTICE
Refitting the gantry interface board.
The gantry interface board is installed on the mount of the new trailing cable.
Service Work
3.5.5 Replacing the Trailing Cable Gantries
Service Manual SIPLACE SX4/DX4 83
To sever the pneumatic hoses, which lead to the pneu-
matic distributor inside the machine base, proceed as fol-
lows:
Place the gauge (1) on the mount (3).
Use the gauge to label the hoses at the Y hose mark
(2). You will need a "white Edding paint marker pen"
for this.
Disconnect the cooling tubes for the Y motor from the
connection piece (4) (machine base).
CAUTION
Before cutting the pneumatic hoses
Label the order of pneumatic hoses as shown on the gauge (from 1 to 7 inside to outside).
This is important to ensure that the hoses are then correctly connected again after cutting.
During cutting, make sure that the pneumatic hoses do not fall into the machine base. Se-
cure them accordingly.
Loosen the outer screws fastening the trailing cable
mount (3).
If the option "Vacuum pump" is available, loosen the
pneumatic hoses (2) and follow the instructions in the
"Vacuum pump SX4/DX4 assembly instructions"
[00196845-xx].
Secure the end of the trailing cable (with cable ties) in
the machine to prevent it hanging loosely and damag-
ing other machine components.