Service Work 3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx] Electric al System Service Manual SIPLACE SX4/DX4 43 3.2.7 3 . 2 . 7 R e p la c in g t h e L o a d A d d C ir c u it ( A 4 ) [ 0 3 0 9 4 5 8 5 S x x ] …

Service Work
Electrical System 3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
42 Service Manual SIPLACE SX4/DX4
3.2.6
3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
Replacing the Rectifiers (U1 to U3, U20 to U24)
Parts, equipment and tools
▪ U1, U3: rectifier S101-B6U 160-08 [00341246-xx]
▪ U2: rectifier S61-B2U 28-10 [03080931-xx]
▪ U20 to U24: rectifier S61-B2U 28-04 [03079959-xx]
▪ Silicon-free heat-conductive paste (not electrically conductive)
Thermal conductivity 1.0 W/mK
Dielectric strength 40kV/mm
Temperature range -40°C to +200°C
Flash point >280°C
Suggested supplier: Bürklin OHG, order number 80 B 531
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
► Unplug all connections to the rectifiers. You may want to mark their positions, to make clear assign-
ment easier later on.
► Loosen the screws fastening the rectifier and remove the rectifier.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Cover
2. Rectifier U24
3. Rectifier U3
4. Rectifier U1
5. Rectifier U2
6. Rectifier U20 to U23
CAUTION
Installation instructions
► Apply a heat-conductive paste between the metal frame and the rectifier.

Service Work
3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx] Electrical System
Service Manual SIPLACE SX4/DX4 43
3.2.7
3.2.7 Replacing the Load Add Circuit (A4) [03094585Sxx]
Replacing the Load Add Circuit (A4) [03094585Sxx]
Parts, equipment and tools
▪ FBG dyn. load add circuit intermediate cycle [03094585Sxx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
► Unplug all connections to the load add circuit. You may want to mark their positions, to make clear
assignment easier later on.
► Loosen the screws fastening the load add circuit and remove it.
Installation
► Follow the removal instructions in reverse order for installation.
1. Cover
2. Line filter (Z1)
3. Load add circuit (A4)

Service Work
Electrical System 3.2.8 Replacing the Line Filter (Z1) [03078386-xx]
44 Service Manual SIPLACE SX4/DX4
3.2.8
3.2.8 Replacing the Line Filter (Z1) [03078386-xx]
Replacing the Line Filter (Z1) [03078386-xx]
Parts, equipment and tools
▪ Line filter for 3-phase systems 36 A (Z1) [03078386-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
► Unplug all connections to the line filter. You may want to mark their positions, to make clear assign-
ment easier later on.
► Loosen the screws fastening the line filter and remove the line filter.
Installation
► Follow the removal instructions in reverse order for installation.
1. Cover
2. Line filter (Z1)
3. Load add circuit (A4)