SIPLACE-SX4-DX4-用户手册.pdf - 第286页

Description of the circuit boards Gantry 6.2.5 X base adapter TWIN [03054879-xx] 286 Service Manual SIPLACE SX4/DX4 6.2.5 6 . 2 . 5 X b a s e a d a p t e r T W I N [ 0 3 0 5 4 8 7 9 - x x ] X base adapter TWIN [03054879-…

100%1 / 298
Description of the circuit boards
6.2.4 X base adapter C&P [03045647-xx] Gantry
Service Manual SIPLACE SX4/DX4 285
Meaning of LEDs H1 - H9
The voltage monitors trigger as soon as the target voltage is exceeded or undershot by 5%.
H1 Ok Status display for the component sensor
H2 RS232 Shines when the programming connector for the HCU1 is connected (not de-
signed for Service)
H3 1V5 Voltage monitor 1.5 V, shines red in event of errors
H4 3V3 Voltage monitor 3.3 V, shines red in event of errors
H5 5V Voltage monitor 5 V, shines red in event of errors
H6 15V Voltage monitor 15 V, shines red in event of errors
H7 DP Voltage monitor DP (currently without function)
H8 24V Voltage monitor 24 V, shines red in event of errors
H9 LOC Voltage monitor local - shines red as soon as one of the voltage monitors trig-
gers (not for 24 V)
Description of the circuit boards
Gantry 6.2.5 X base adapter TWIN [03054879-xx]
286 Service Manual SIPLACE SX4/DX4
6.2.5
6.2.5 X base adapter TWIN [03054879-xx]
X base adapter TWIN [03054879-xx]
From version -03:
03054879-03/-04
LED [03054879-03]
X4
X14
X15
Connections for HCU (TwinHead
module 2)
X9
X16
X17
Connections for HCU (TwinHead
module 1)
X30
X31
Connections for TwinHead module 2 X32
X33
Connections for TwinHead module 1
X3 Connection on the head interface Hx LEDs (see below)
LED Color Status Signal name Description
H2 GN ON - HCU2 programming connector connected
H3 RD ON FPGA_TEST_6 1.5VDC PowerFail
H4 RD ON FPGA_TEST_2 3.3VDC PowerFail
H5 RD ON FPGA_TEST_4 5VDC PowerFail
H6 RD ON FPGA_TEST_1 15VDC PowerFail
H7 RD ON FPGA_TEST_3 DP PowerFail, not used
H8 RD ON FPGA_TEST_5 24VDC PowerFail
H9 RD ON POWERFAIL_LOCAL PowerFail board:
ON, when 1.5VDC, 3.3VDC, 5VDC and 15VDC
are outside the permissible tolerance
Description of the circuit boards
6.2.5 X base adapter TWIN [03054879-xx] Gantry
Service Manual SIPLACE SX4/DX4 287
Older versions:
Base adapter board (without HCU)
LEDs - meanings
The voltage monitors trigger as soon as the nominal voltage is undershot by 5%.
1 LEDs H1-H13 2 X4, X14, X15 – connector for HCU1
3 X3 – connector to the gantry interface
board C700
4 X11 – service connector for checking the
voltages
5 X9, X16, X17 – connector for HCU2 6 X32, X33 connector for segment 2 flat rib-
bon cable
7 X30, X31 connector for segment 1 flat rib-
bon cable
8 DIP switches S1 and S2
9 7-segment displays
LED Description
H1 RS232 Lights up when the HCU1 programming connector is plugged in
H2 RS232 Lights up, when the HCU2 programming connector is plugged in
H3 1V5 1.5 V voltage monitoring - lights up red in case of an error
H4 3V3 3.3 V voltage monitoring - lights up red in case of an error
H5 5V 5 V voltage monitoring - lights up red in case of an error
H6 15V 15 V voltage monitoring - lights up red in case of an error
H7 DP DP voltage monitoring – (currently without function)
H8 24V 24 V voltage monitoring - lights up red in case of an error
H9 LOC Voltage monitoring local - lights up as soon as the voltage monitors triggers.
H10 Ok HCU1-OK - HCU running without errors
H11 ERR HCU1 error - HCU reports an error
H12 Ok HCU2-OK - HCU running without errors
H13 ERR HCU2 error - HCU reports an error