SIPLACE-SX4-DX4-用户手册.pdf - 第179页

Service Work 3.10.7 Replacing the Control Valve [03097252-xx] COT insert Service Manual SIPLACE SX4/DX4 179 3.10.7 3 . 1 0 . 7 R e p la c in g t h e C o n t r o l V a lv e [ 0 3 0 9 7 2 5 2 - x x ] Replacing the Contro l…

100%1 / 298
Service Work
COT insert 3.10.6 Replacing the Empty-Tape Duct Assembly [03052576-xx]
178 Service Manual SIPLACE SX4/DX4
Carefully lift the empty-tape duct (2) out of the COT insert (1).
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instructions:
Fit the sensors (reed contacts) for the reject container.
Fit the empty-tape duct.
When fitting the nozzle changer, observe the applicable assembly instructions, as you need to check
the installation height.
See also
3.8.1 Replacing the Nozzle Changer [ ➙ 152]
3.13.2 Removing the Back Section of the Manual Table [ ➙ 201]
3.13.3 Removing the Front Section of the Manual Table [ ➙ 202]
3.13.2 Removing the Back Section of the Manual Table [ ➙ 201]
3.13.3 Removing the Front Section of the Manual Table [ ➙ 202]
NOTICE
Unplug the cable from the FCU.
You could also unplug the cable at the FCU. This gives you greater freedom of movement.
In this case, note the positions, to make clear assignment easier later on.
CAUTION
Risk of cutting
The cutter is located under the tape channel. The blades there have very sharp edges.
Do not reach into the cutter and make sure that it is never left unmonitored or freely acces-
sible.
NOTICE
These sensors are installed in different positions, according to the configuration of the machine.
Refer to the appropriate assembly instructions:
Service Work
3.10.7 Replacing the Control Valve [03097252-xx] COT insert
Service Manual SIPLACE SX4/DX4 179
3.10.7
3.10.7 Replacing the Control Valve [03097252-xx]
Replacing the Control Valve [03097252-xx]
Parts, equipment and tools
Valve assembly SX4 [03097252-xx]
Overview
Removal
Loosen the screws fastening the COT insert and extract it slightly from the machine. (See "3.10.1
Replacing the COT Insert Assembly [03080552-xx]" [ ➙ 170])
Dismantle the cover plate over the valve.
Unplug the electricity and compressed air cables from the control valve (1). Mark their positions, to
make clear assignment easier later on.
Loosen the fastening screws and remove the control valve.
Installation
Installation is performed by following the above instructions in the reverse order.
Control valve
1
Service Work
COT insert 3.10.8 Replacing the Baffles
180 Service Manual SIPLACE SX4/DX4
3.10.8
3.10.8 Replacing the Baffles
Replacing the Baffles
Read the relevant section of the user manual for your machine.
Parts, equipment and tools
Guide plate (for number please refer to the parts catalogue.)
Overview
1. Empty-tape duct assembly
2. Baffles
1. Deflection plate
2. Screws fastening the deflection plate (left and right)
1
2