Description of the circuit boards 6.3.3 Conveyor control TSP410 Conveyor Service Manual SIPLACE SX4/DX4 291 6.3.3 6 . 3 . 3 C o n v e y o r c o n t r o l T S P 4 1 0 Conveyor control TSP410 Conveyor control [ 03077468-xx…

100%1 / 298
Description of the circuit boards
Conveyor 6.3.2 Conveyor control TSP410P, power module [03077469-xx]
290 Service Manual SIPLACE SX4/DX4
Dip switch S4 [03077468-02]
Jumper [03077468-02]
6.3.2
6.3.2 Conveyor control TSP410P, power module [03077469-xx]
Conveyor control TSP410P, power module [03077469-xx]
03077469-03
LED [03077469-03]
Switch Status Signal name Description
S4.1 OFF /DIP7 Reserved
S4.2 OFF /DIP8 Reserved
S4.3 OFF /DIP9 Reserved
S4.4 OFF /DIP10 Reserved
Jumper Status Description
JP1 OFF No 120 ohms CAN resistor
JP2 1-2 No 120 ohms CAN resistor
JP3 OFF Jumper set to 1-2: FPGA download cable connected
LED Color Status Signal name Description
H5 GN ON PM1_1 +40VDC OK (placement area 1)
H6 GN ON PM1_2 +40VDC OK (placement area 2)
H7 GN ON +24V +24VDC OK
H8 GN ON P_BRAKE Supply voltage for lifting table brake OK
Description of the circuit boards
6.3.3 Conveyor control TSP410 Conveyor
Service Manual SIPLACE SX4/DX4 291
6.3.3
6.3.3 Conveyor control TSP410
Conveyor control TSP410
Conveyor control [03077468-xx]/[03077469-xx]
Description of the circuit boards
COT insert 6.4.1 Connecting assy FCU [03059783-xx]
292 Service Manual SIPLACE SX4/DX4
6.4
6.4 COT insert
COT insert
6.4.1
6.4.1 Connecting assy FCU [03059783-xx]
Connecting assy FCU [03059783-xx]
03059783-04
LED (test mode for reject box switched off – S2.1 ON) [03059783-04]
LED (test mode for reject box switched on – S2.1 OFF) [03059783-04]
Button S1 [03059783-04]
Dip switch S2 [03059783-04]
LED Color Status Signal name Description
H1, H2, H3, H4 GN Sequential shift
light
LED1, 2, 3, 4 FCU OK
H1, H2, H3, H4 GN ON LED1, 2, 3, 4 eSW application missing
H1, H2, H3, H4 GN Flashing LED1, 2, 3, 4 FCU error, reboot place-
ment machine or replace
FCU
LED Color Status Signal name Description
H1 or H2 or H3 or
H4
GN Flashes LED1 or 2 or 3 or
4
No sensor connected for
reject box 1 or 2 or 3 or 4
H1 or H2 or H3 or
H4
GN OFF LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
H1 or H2 or H3 or
H4
GN ON LED1 or 2 or 3 or
4
Sensor for reject boxes 1 or
2 or 3 or 4 connected, but
no reject box inserted
Buttons Status Function Description
S1 OFF RESET When pressed
Switch Status Signal name Description
S2.1 ON/OFF FCU_ENV3 ON: test mode for reject box switched off
OFF: test mode for reject box switched on
S2.2 OFF FCU_ENV2 40-fold FCU
S2.3 ON/OFF FCU_ENV1 ON: without insert control, with virtual button
OFF: with insert control, without virtual button
S2.4 ON/OFF FCU_ENV0 ON: with tape cutter and with nozzle changer
functionality
OFF: without tape cutter and without nozzle
changer functionality