SIPLACE-SX4-DX4-用户手册.pdf - 第65页

Service Work 3.4.4 Replacing the Pressure Regulator (Location 1) [0 3062103-x x] Pneumatic System Service Manual SIPLACE SX4/DX4 65 3.4.4 3 . 4 . 4 R e p la c in g t h e P r e s s u r e R e g u la t o r ( L o c a t io n …

100%1 / 298
Service Work
Pneumatic System 3.4.2 Sealing the Screwed Connections
64 Service Manual SIPLACE SX4/DX4
3.4.2
3.4.2 Sealing the Screwed Connections
Sealing the Screwed Connections
3.4.3
3.4.3 Dismantling the Lower Side Cover
Dismantling the Lower Side Cover
NOTICE
Sealing the Screwed Connections
If compressed air screwed connections are loosened, these will need to be sealed again after-
wards. Always use the same sealing technique as was used before they were removed.
There are several different sealing techniques:
Sealing ring (rubber or plastic)
These are either supplied or you can use the ones used before. Check the condition of the
sealing rings for damage.
Sealant
There are several variants of this:
Loctite 567 [03097172-xx] and Loctite 55 [03092492-xx] – after loosening the connection,
clean the screwed thread and seal it with Loctite. The sealing thread for Loctite 55 must be
wound on in the direction of the screwed thread.
There may also already be a sealant on the screwed thread.
Most tasks performed on the pneumatic system require
that you dismantle the lower side cover.
To do this, loosen the 6 screws fastening the side
cover in the order (1) to (4) and remove these. While
unscrewing, always hold on to the side cover, to pre-
vent it falling off.
Carefully pull out the side cover.
Service Work
3.4.4 Replacing the Pressure Regulator (Location 1) [03062103-xx] Pneumatic System
Service Manual SIPLACE SX4/DX4 65
3.4.4
3.4.4 Replacing the Pressure Regulator (Location 1) [03062103-xx]
Replacing the Pressure Regulator (Location 1) [03062103-xx]
Parts, equipment and tools
Pressure regulator G1/2 Mod112 (34203054) [03062103-xx]
▪Sealant
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
To do this, loosen the screws fastening the side cover and remove these. (See "3.4.3 Dismantling
the Lower Side Cover" [ ➙ 64])
Loosen the screwed clamps at the top and bottom of the pressure regulator.
Carefully remove the pressure regulator.
1. Main valve
2. Safety valve
3. Pressure regulator
CAUTION!
When working on the pneumatic system, always switch
off the compressed air supply.
Push the lever (1) for the compressed air supply
back, until it is positioned horizontally.
Open the screw (2) on the inlet filter to vent the sys-
tem.
All manometers must be set to zero.
Service Work
Pneumatic System 3.4.5 Replacing the Proportional Controller (Location 4) [03065425-xx]
66 Service Manual SIPLACE SX4/DX4
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
3.4.5
3.4.5 Replacing the Proportional Controller (Location 4) [03065425-xx]
Replacing the Proportional Controller (Location 4) [03065425-xx]
Parts, equipment and tools
Proportional controller Sentronic-D DN8 SUBB1/4 10 bar [03065425-xx]
Adapter plate proportional valve [03082780-xx] (seal)
ISO4762-M4x70-A2-70 [03082432-xx]
Overview
CAUTION
Installation instructions
Seal the compressed air system with sealant. Observe the instructions in section "3.4.2
Sealing the Screwed Connections" [ 64] in connection with this.
NOTICE
Parameter
The proportional controller is supplied with the latest parameters preset. Subsequent program-
ming is not possible.
1. Proportional controller top and bottom