SIPLACE-SX4-DX4-用户手册.pdf - 第233页

Settings 5.2.1 Overview of Electrics Electrical and Control Settings Service Manual SIPLACE SX4/DX4 233 5.2 5 . 2 E le c t r ic a l a n d C o n t r o l S e t t in g s Electrical and Control Settings 5.2.1 5 . 2 . 1 O v e…

100%1 / 298
Settings
Settings on the Basic Machine 5.1.1 Setting the Machine Covers
232 Service Manual SIPLACE SX4/DX4
5.1.1.6
5.1.1.6 Setting the Cover Rollers
Setting the Cover Rollers
Cover rollers (example of SX2 shown)
Set the cover roller by using the grub screw, so that it is inserted by at least 75% into the guidance.
Lock the roller with a setscrew DIN915-M8x16 [00304354-xx] or DIN-EN-ISO4026-M8x16-A2-21H
[03025582-xx].
NOTICE
Missing O-rings
Replace the following missing O-rings on the roller: O-ring 8.5x1.6 [03078577-xx]
Settings
5.2.1 Overview of Electrics Electrical and Control Settings
Service Manual SIPLACE SX4/DX4 233
5.2
5.2 Electrical and Control Settings
Electrical and Control Settings
5.2.1
5.2.1 Overview of Electrics
Overview of Electrics
CAUTION
Observe the detailed circuit diagrams!
For more detailed information, refer to the circuit diagrams folder of your machine.
SIPLACE SX4/DX4 detailed circuit diagrams [00196711-xx] (German/English)
Circuit diagram SIPLACE X-Series S [00197021-xx] (German/English)
Settings
Electrical and Control Settings 5.2.2 Setting the Voltage on the Pulsed Power Packs
234 Service Manual SIPLACE SX4/DX4
5.2.2
5.2.2 Setting the Voltage on the Pulsed Power Packs
Setting the Voltage on the Pulsed Power Packs
Parts, equipment and tools
Voltage measuring device
Overview
SX4 X34iS – Ov erview of Pul sed Power Pac ks
The pulsed power packs are located in the rack unit be-
tween location 3 and 4.
A5) Pulsed power pack (24 VDC, set to 25 VDC)
for Power Fail, safety circuit SSK, tape cutter, PCB Han-
dling
The power fail signal is generated by the pulsed power
pack A5 and sent to the GCU and HCU. (X200:9,
X200:10)
A6) Pulsed power pack (27 VDC)
for FCU (gantry 1 and 4)
A7) Pulsed power pack (27 VDC)
for FCU (gantry 2 and 3)
A8) Pulsed power pack (36 VDC, to be set to 42 VDC)
For HCU (gantry 1 to 4)
NOTICE!
NOTICE! Check the set values and correct if
necessary.
To A5:
The following fuses have 24 V present:
F10: Conveyor electrics
F11: Y motor fan, safety circuit (internal)
F12: Distributor power (line 1)
F13: Distributor power (line 2)
F14: Power fail
F20: Cover fan, gantry 1 and 4
F21: Cover fan, gantry 2 and 3