SIPLACE-SX4-DX4-用户手册.pdf - 第192页

Service Work Docking Station for X-Series Component Trolley 3.12.3 Replacing the Locking Unit Short-Stroke Cylinder [030348 31-XX] 192 Service Manual SIPLACE SX4/DX4 3.12.3 3 . 1 2 . 3 R e p la c in g t h e L o c k in g …

100%1 / 298
Service Work
3.12.2 Replacing the Micro Fuse [03033387-XX] Docking Station for X-Series Component Trolley
Service Manual SIPLACE SX4/DX4 191
3.12.2
3.12.2 Replacing the Micro Fuse [03033387-XX]
Replacing the Micro Fuse [03033387-XX]
Parts, equipment and tools
Microfuse [03033387-xx]
Overview
Replacing the micro switch
Open the cover (1) on the micro fuse.
Pull out the micro fuse.
Insert the new micro fuse and close the cover (1).
Connect the connection cable (3) and press the ON/OFF button to switch on (2).
1. Position of micro fuse (T 8.0 A)
1
1. Position of micro fuse (T 8.0 A)
2. ON / OFF switch
3. Power supply plug
DANGER!
Switch off the voltage supply
Press the ON/OFF button (2) to switch off, and discon-
nect the power supply (3).
1
3
2
Service Work
Docking Station for X-Series Component Trolley 3.12.3 Replacing the Locking Unit Short-Stroke Cylinder [03034831-XX]
192 Service Manual SIPLACE SX4/DX4
3.12.3
3.12.3 Replacing the Locking Unit Short-Stroke Cylinder [03034831-XX]
Replacing the Locking Unit Short-Stroke Cylinder [03034831-XX]
Parts, equipment and tools
Short-stroke cylinder [03034831-xx]
Overview
Removal
Installation
Install the locking slider (3) on the new short-stroke cylinder (2).
Reconnect to the compressed air supply.
Clean the locking sliders (3) and the guidance block (5) with a clean, lint-free cloth and lubricate both
slightly with Unisilikon.
Move the locking slider (3) into the guidance block, so that the beveled side (4) is pointing to the front
(in the direction of travel). This is important when moving the component trolley in.
Fit the short-stroke cylinder with the two fastening screws.
Switch the compressed air supply on again and check that the left and right locking sliders move out
at the same time.
If necessary, adjust the throttle valve (6) on the short-stroke cylinder.
1. Installation position of left locking unit
2. Installation position of right locking unit
CAUTION!
Risk of injury when disconnecting pressurized com-
pressed air lines.
Switch off the compressed air supply.
Loosen the two screws (1) fastening the short-stroke
cylinder (2).
Pull the short-stroke cylinder (2) and the locking slider
(3) downwards and out of the guidance block (5).
Loosen the pneumatic connections on the short-
stroke cylinder.
Unscrew the locking slider (3) from the short-stroke
cylinder (2).
5
1
4
3
2
Service Work
3.12.4 Replacing the Locking Lever [03025104-XX] Docking Station for X-Series Component Trolley
Service Manual SIPLACE SX4/DX4 193
3.12.4
3.12.4 Replacing the Locking Lever [03025104-XX]
Replacing the Locking Lever [03025104-XX]
Parts, equipment and tools
Locking lever [03025104-xx]
Overview
Removal
Installation
Loosely screw in the new locking lever.
Align the locking lever to the edge (3) and tighten the four fastening screws.
Check that the limit switch (4) is actuated when the locking lever is closed. Correct the position of
the locking lever, where necessary.
Check the position end switch function, by trying out the locking procedure.
1. Locking lever – on the left side
2. Locking lever – on the right side
1
2
1. Locking lever
2. Four fastening screws
3. Position end switch
Loosen the four screws (2) (two each at the top and
bottom) fastening the locking lever (1).
Remove the locking lever.
4
3
2
1