Service Work Vacuum Pump 3.14.1 Replacing the Vacuum Pump [03069679-xx] 214 Service Manual SIPLACE SX4/DX4 3.14 3 . 1 4 V a c u u m P u m p Vacuum Pump 3.14.1 3 . 1 4 . 1 R e p la c in g t h e V a c u u m P u m p [ 0 3 0…

Service Work
3.13.11 Replacing the Insert Feeder [03002898-xx] Manual Table (DX4)
Service Manual SIPLACE SX4/DX4 213
3.13.11
3.13.11 Replacing the Insert Feeder [03002898-xx]
Replacing the Insert Feeder [03002898-xx]
Parts, equipment and tools
Select the right insert feeder:
Removal
► Move the component trolley out of the machine.
► Loosen the screw fastening the guide profile and remove the guide profile.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
Insert feeder [03002898-xx]
Suitable for:
▪ X-Series component trolley
▪ Component trolley SX1/SX2 (30 or 60 tracks)
▪ Manual table X-Series S
Insert feeder [03085635-xx]
Suitable for:
▪ Manual table DX series
CAUTION
Installation instructions
► Make sure that the insert is aligned properly with the guidance behind it. You must be able
to push feeder modules into the feeder location without edge interference.

Service Work
Vacuum Pump 3.14.1 Replacing the Vacuum Pump [03069679-xx]
214 Service Manual SIPLACE SX4/DX4
3.14
3.14 Vacuum Pump
Vacuum Pump
3.14.1
3.14.1 Replacing the Vacuum Pump [03069679-xx]
Replacing the Vacuum Pump [03069679-xx]
Parts, equipment and tools
▪ Vacuum pump Becker VX4 25 [03069679-xx]
▪ Assembly instructions for vacuum pump SX4, X series S" [00196845-xx]
Removal/installation
► Also read the "Assembly instructions for the vacuum pump SX4, X series S" [00196845-xx].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.2
3.14.2 Replacing the Exhaust Tube [03087599-xx]
Replacing the Exhaust Tube [03087599-xx]
Parts, equipment and tools
▪ Exhaust tube ID100 [03087599-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Loosen the two screws fastening the hose holder. The hose holder has two keyholes. The fastening
screws do not need to be completely loosened.
► Turn the hose holder a little and remove it.
► Open the hose clamp and remove the hose.
Installation
► Follow the removal instructions in reverse order for installation.
1. Exhaust tube
2. Hose clamp
3. Hose holder
The exhaust tube is fixed to the underside of the ma-
chine.

Service Work
3.14.3 Replacing the Connector Unit Box Vacuum Pump
Service Manual SIPLACE SX4/DX4 215
3.14.3
3.14.3 Replacing the Connector Unit Box
Replacing the Connector Unit Box
Parts, equipment and tools
▪ Vacuum pump connector unit box [03079448-xx]
Overview
Connection on the connector unit box.
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
► Dismantle the waste slide for better access. (See "3.9.8 Replacing the Used Tape Chute [03067460-
xx]" [ ➙ 168])
► Unplug all electrical connections from the connector unit box. Mark their positions, to make clear as-
signment easier later on.
► Take the connector unit box out of the machine.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
Connector unit box
The connector unit box is located at the bottom of the ma-
chine frame, at location 2.
Terminal Description
X2qr Voltage
X3qr Control
X4qr, X5qr Pumps (sequence not important)
If only one pump is installed, the second connection must be closed with a bridge con-
nector.
X6qr Fan
CAUTION
Installation instructions
► If not present, the suppressor module must be removed from the old connector unit box and
fitted in the new one. (See "3.14.5 Replacing the Suppressor Module in the Connector Unit
Box [03097216-xx]" [ ➙ 217])