SIPLACE-SX4-DX4-用户手册.pdf - 第64页

Service Work Pneumatic System 3.4.2 Sealing the Screwed Connections 64 Service Manual SIPLACE SX4/DX4 3.4.2 3 . 4 . 2 S e a lin g t h e S c r e w e d C o n n e c t io n s Sealing the Screwed Connections 3.4.3 3 . 4 . 3 D…

100%1 / 298
Service Work
3.4.1 Pneumatic System - Overview Pneumatic System
Service Manual SIPLACE SX4/DX4 63
3.4
3.4 Pneumatic System
Pneumatic System
Pneumat ic System - Using th e Correc t Blanking Plugs
3.4.1
3.4.1 Pneumatic System - Overview
Pneumatic System - Overview
The pneumatic system is located at locations 1, 3 and 4, behind the side covers.
CAUTION
Switch off the compressed air supply.
When working on the pneumatic system, always disconnect the machine from the compressed
air supply.
CAUTION
Use the correct blanking plugs
Only use blanking plugs in the machine which match the manufacturer's compressed air
connection. A tight fit cannot be guaranteed for other blanking plugs.
We recommend the use of blanking plugs made by Festo.
1. Location 3, behind the side cover: Elmo blower with
electrics, cooling air filter
2. Location 4, behind the side cover
3. Proportional controller for gantry group of placement
heads PA1/PA2
1. Location 1, behind the side cover: connection cou-
pling, main valve with compressed air filter, com-
pressed air displays
2. Location 1, at the bottom, in the machine base: com-
pressed air connection for gantry trailing cable and
vacuum pump option
3. 5/2 way valve [03062277-xx]
Main valve (X59) for NC, input, conveyor
4. 5/2 solenoid valve [00344974-xx]
Safety valve (X60) for tape cutter
5. Pressure regulator [03062103-xx]
Service Work
Pneumatic System 3.4.2 Sealing the Screwed Connections
64 Service Manual SIPLACE SX4/DX4
3.4.2
3.4.2 Sealing the Screwed Connections
Sealing the Screwed Connections
3.4.3
3.4.3 Dismantling the Lower Side Cover
Dismantling the Lower Side Cover
NOTICE
Sealing the Screwed Connections
If compressed air screwed connections are loosened, these will need to be sealed again after-
wards. Always use the same sealing technique as was used before they were removed.
There are several different sealing techniques:
Sealing ring (rubber or plastic)
These are either supplied or you can use the ones used before. Check the condition of the
sealing rings for damage.
Sealant
There are several variants of this:
Loctite 567 [03097172-xx] and Loctite 55 [03092492-xx] – after loosening the connection,
clean the screwed thread and seal it with Loctite. The sealing thread for Loctite 55 must be
wound on in the direction of the screwed thread.
There may also already be a sealant on the screwed thread.
Most tasks performed on the pneumatic system require
that you dismantle the lower side cover.
To do this, loosen the 6 screws fastening the side
cover in the order (1) to (4) and remove these. While
unscrewing, always hold on to the side cover, to pre-
vent it falling off.
Carefully pull out the side cover.
Service Work
3.4.4 Replacing the Pressure Regulator (Location 1) [03062103-xx] Pneumatic System
Service Manual SIPLACE SX4/DX4 65
3.4.4
3.4.4 Replacing the Pressure Regulator (Location 1) [03062103-xx]
Replacing the Pressure Regulator (Location 1) [03062103-xx]
Parts, equipment and tools
Pressure regulator G1/2 Mod112 (34203054) [03062103-xx]
▪Sealant
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
To do this, loosen the screws fastening the side cover and remove these. (See "3.4.3 Dismantling
the Lower Side Cover" [ ➙ 64])
Loosen the screwed clamps at the top and bottom of the pressure regulator.
Carefully remove the pressure regulator.
1. Main valve
2. Safety valve
3. Pressure regulator
CAUTION!
When working on the pneumatic system, always switch
off the compressed air supply.
Push the lever (1) for the compressed air supply
back, until it is positioned horizontally.
Open the screw (2) on the inlet filter to vent the sys-
tem.
All manometers must be set to zero.