Service Work Vacuum Pump 3.14.6 Replacing the Circuit Breaker in the Connecto r Unit Box [0 3079445-xx] 218 Service Manual SIPLACE SX4/DX4 3.14.6 3 . 1 4 . 6 R e p la c in g t h e C ir c u it B r e a k e r in t h e C o n…

100%1 / 298
Service Work
3.14.5 Replacing the Suppressor Module in the Connector Unit Box [03097216-xx] Vacuum Pump
Service Manual SIPLACE SX4/DX4 217
3.14.5
3.14.5 Replacing the Suppressor Module in the Connector Unit Box [03097216-xx]
Replacing the Suppressor Module in the Connector Unit Box [03097216-xx]
Parts, equipment and tools
EMC suppressor module RC 3x400V 575VAC 4kW [03097216-xx]
Overview
Removal
The suppressor module is located in the connector unit box. The connector unit box is located at the bot-
tom of the machine frame, at location 2.
For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
Installation
Observe the following instructions during installation:
See also
1.2 Preparatory Work... [ ➙ 12]
Suppressor module
Connector unit box
1. Installation location of suppressor module
2. The suppressor module is connected to terminal 2, 4
and 6.
NOTICE
Installation instructions
Cut off the cable lugs and remove approx. 1 cm of insulation from the end of the cable.
Unlock the terminals (e.g. with a screwdriver) and insert one cable each into terminals 2, 4
and 6.
Service Work
Vacuum Pump 3.14.6 Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
218 Service Manual SIPLACE SX4/DX4
3.14.6
3.14.6 Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
Replacing the Circuit Breaker in the Connector Unit Box [03079445-xx]
Parts, equipment and tools
Circuit breaker 5SY6 3pol 6A C [03079445-xx]
Removal/Installation
The circuit breaker is located in the connector unit box. The connector unit box is located at the bottom
of the machine frame, at location 2.
For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.7
3.14.7 Replacing the Button in the Connector Unit Box [03072025-xx]
Replacing the Button in the Connector Unit Box [03072025-xx]
Parts, equipment and tools
Button 5TE4 800 [03072025-xx]
Removal/Installation
The button is located in the connector unit box. The connector unit box is located at the bottom of the
machine frame, at location 2.
For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.8
3.14.8 Replacing the Relay Terminal Block in the Connector Unit Box [03086538-xx]
Replacing the Relay Terminal Block in the Connector Unit Box [03086538-xx]
Parts, equipment and tools
Relay terminal block DEK-REL-G24/21 24VDC 1 Wech [03086538-xx]
Removal/Installation
The relay terminal block is located in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
3.14.9
3.14.9 Replacing the Diode Terminal Block in the Connector Unit Box [03006763-xx]
Replacing the Diode Terminal Block in the Connector Unit Box [03006763-xx]
Parts, equipment and tools
Diode terminal block 2.5 qmm gy 4L. with 1N4007 [03006763-xx]
Removal/Installation
The diode terminal block is located in the connector unit box. The connector unit box is located at the
bottom of the machine frame, at location 2.
For more information about this, read section "3.14.3 Replacing the Connector Unit Box " [ ➙ 215].
See also
1.2 Preparatory Work... [ ➙ 12]
Measuring Equipment and Tools
Calibration Tool [03010565-xx]
Service Manual SIPLACE SX4/DX4 219
4
4 Measuring Equipment and Tools
Measuring Equipment and Tools
4.1
4.1 Calibration Tool [03010565-xx]
Calibration Tool [03010565-xx]
4.2
4.2 Calibration Tool [03034148-xx]
Calibration Tool [03034148-xx]
Use:
The calibration tool [03010565-xx] is used for calibration
of the DLM, CPP, P&P heads, TwinHead and PCB cam-
era.
Use:
The calibration tool is used for the following placement
heads:
C&P20
C&P20 A
C&P20 M
C&P20 P
CPP (only at X4i S without stationary camera)