SIPLACE-SX4-DX4-用户手册.pdf - 第41页

Service Work 3.2.5 Replacing the AC/DC Converter ( Pulsed Power Packs A5 to A 8) Electrical System Service Manual SIPLACE SX4/DX4 41 Removal ► Switch off the machine, disconnec t it from the po wer supply and secure it t…

100%1 / 298
Service Work
Electrical System 3.2.5 Replacing the AC/DC Converter (Pulsed Power Packs A5 to A8)
40 Service Manual SIPLACE SX4/DX4
3.2.5
3.2.5 Replacing the AC/DC Converter (Pulsed Power Packs A5 to A8)
Replacing the AC/DC Converter (Pulsed Power Packs A5 to A8)
Parts, equipment and tools
AC/DC converter (pulsed power pack – A5, A6, A7) [03055232-xx]
AC/DC converter (pulsed power pack – A8) [03076588-xx]
Overview
SX4 X34iS – Ov erview of Pul sed Power Pac ks
The pulsed power packs are located in the rack unit be-
tween location 3 and 4.
A5) Pulsed power pack (24 VDC, set to 25 VDC)
for Power Fail, safety circuit SSK, tape cutter, PCB Han-
dling
The power fail signal is generated by the pulsed power
pack A5 and sent to the GCU and HCU. (X200:9,
X200:10)
A6) Pulsed power pack (27 VDC)
for FCU (gantry 1 and 4)
A7) Pulsed power pack (27 VDC)
for FCU (gantry 2 and 3)
A8) Pulsed power pack (36 VDC, to be set to 42 VDC)
For HCU (gantry 1 to 4)
NOTICE!
NOTICE! Check the set values and correct if
necessary.
To A5:
The following fuses have 24 V present:
F10: Conveyor electrics
F11: Y motor fan, safety circuit (internal)
F12: Distributor power (line 1)
F13: Distributor power (line 2)
F14: Power fail
F20: Cover fan, gantry 1 and 4
F21: Cover fan, gantry 2 and 3
Service Work
3.2.5 Replacing the AC/DC Converter (Pulsed Power Packs A5 to A8) Electrical System
Service Manual SIPLACE SX4/DX4 41
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Unplug all connections to the module. You may want to mark their positions, to make clear assign-
ment easier later on.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
To release the module, press the lever (1) at the back
of the module down and then pull the module off the
rail.
CAUTION
Installation instructions
Set the voltage. (See "5.2.2 Setting the Voltage on the Pulsed Power Packs" [ ➙ 234])
Service Work
Electrical System 3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
42 Service Manual SIPLACE SX4/DX4
3.2.6
3.2.6 Replacing the Rectifiers (U1 to U3, U20 to U24)
Replacing the Rectifiers (U1 to U3, U20 to U24)
Parts, equipment and tools
U1, U3: rectifier S101-B6U 160-08 [00341246-xx]
U2: rectifier S61-B2U 28-10 [03080931-xx]
U20 to U24: rectifier S61-B2U 28-04 [03079959-xx]
Silicon-free heat-conductive paste (not electrically conductive)
Thermal conductivity 1.0 W/mK
Dielectric strength 40kV/mm
Temperature range -40°C to +200°C
Flash point >280°C
Suggested supplier: Bürklin OHG, order number 80 B 531
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Loosen the screws fastening the cover and swing the cover towards the front. The pulsed power
packs are fitted to the cover. These are swung open together with the cover.
Unplug all connections to the rectifiers. You may want to mark their positions, to make clear assign-
ment easier later on.
Loosen the screws fastening the rectifier and remove the rectifier.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Cover
2. Rectifier U24
3. Rectifier U3
4. Rectifier U1
5. Rectifier U2
6. Rectifier U20 to U23
CAUTION
Installation instructions
Apply a heat-conductive paste between the metal frame and the rectifier.