SIPLACE-SX4-DX4-用户手册.pdf - 第181页
Service Work 3.10.8 Replacing the Baffles COT insert Service Manual SIPLACE SX4/DX4 181 Removal ► Loosen the two screws fastening the baffle insert and remove th e baffle. Installation ► Installation is performed by fo l…

Service Work
COT insert 3.10.8 Replacing the Baffles
180 Service Manual SIPLACE SX4/DX4
3.10.8
3.10.8 Replacing the Baffles
Replacing the Baffles
► Read the relevant section of the user manual for your machine.
Parts, equipment and tools
▪ Guide plate (for number please refer to the parts catalogue.)
Overview
1. Empty-tape duct assembly
2. Baffles
1. Deflection plate
2. Screws fastening the deflection plate (left and right)
1
2

Service Work
3.10.8 Replacing the Baffles COT insert
Service Manual SIPLACE SX4/DX4 181
Removal
► Loosen the two screws fastening the baffle insert and remove the baffle.
Installation
► Installation is performed by following the above instructions in the reverse order. Also observe the
following instructions:
CAUTION
Do not dismantle the empty-tape duct.
Only replace the deflection plate assembly. Do not dismantle the empty-tape duct.
NOTICE
Inner baffle
When using tape reels with deep pockets, you may need to remove the inner baffle. Refer to
the operating manual of your machine for details.
All screws are accessible in the installed state. The baffles can therefore be replaced inside the
machine.
CAUTION
Installation instructions
► Reposition the deflection plate on the tape channel, if you are not using any components >
15 mm.
CAUTION
The deflection plate fits tightly into the tape channel.
Sharp-edged objects can damage the coating in the tape channel, which can then lead to com-
ponent tapes getting jammed at the edges. This could then cause a head crash.
► Never use sharp-edged objects to position the deflection plate.
► If necessary, use a wooden wedge or, as shown in the following diagram, a brush with
wooden handle.

Service Work
COT insert 3.10.9 Replacing the Feed Control [03082077-xx]
182 Service Manual SIPLACE SX4/DX4
3.10.9
3.10.9 Replacing the Feed Control [03082077-xx]
Replacing the Feed Control [03082077-xx]
Parts, equipment and tools
▪ Insert control assembly SX4 [03082077-xx]
Overview
Removal
► Switch off the machine and secure it to prevent unauthorized reactivation. Observe the instructions
in section "1.2 Preparatory Work..." [ ➙ 12].
► Dismantle the nozzle changer over the feed control. (See "3.8.1 Replacing the Nozzle Changer"
[ ➙ 152])
► To gain better access, you may need to disconnect the COT insert and pull it slightly out of the ma-
chine. Observe the instructions in section Installation Position for COT Insert (Table Positions).
Alternatively, you can improve access by removing the upper section of the component camera.
► Unplug all electrical connections to the insert control. You may want to mark their positions, to make
clear assignment easier later on.
► Loosen the screws fastening the insert control and remove the insert control from the machine.
Installation
► Follow the removal instructions in reverse order for installation.
See also
3.10.1 Replacing the COT Insert Assembly [03080552-xx] [ ➙ 170]
1. Insert control
CAUTION
Component Camera
► The component camera mirror has sharp edges.
► Take care not to damage the component camera.