Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 12].
Unplug the flat ribbon cable from the connector.
Loosen the two fastening screws.
Pull the flat ribbon cable out of the side of the connector. You may have to lift the feeder unlocking
device slightly to do this.
Lift the feeder unlocking device up and off and unplug the pneumatic connection.
CAUTION
Feeder unlocking device on the manual table
Replacement of the feeder unlocking device on the manual table is the same as that for the
COT insert. However, you need to first dismantle the front and back sections for the manual
table.
This section describes replacement using the example of the COT insert.
1. Feeder unlocking device (under the FCU)
2. Feeder control unit (FCU)
The feeder unlocking device is installed at the locations
in the COT insert.
1. Two fastening screws
2. Complete feeder unlocking device
3. Connector for flat ribbon cable
2
1
1
1
3
2
Service Work
COT insert 3.10.4 Replacing the Unlocking Pins [03088220-xx]
174 Service Manual SIPLACE SX4/DX4
Installation
Reconnect the system to the electrical and compressed air systems.
Carefully press the feeder unlock device towards the back and insert the fastening screws.
3.10.4
3.10.4 Replacing the Unlocking Pins [03088220-xx]
Replacing the Unlocking Pins [03088220-xx]
Parts, equipment and tools
Snipe nose pliers [00353833-xx]
NOTICE
Pneumatic connection
You might find it advisable to loosen the cover on the back of the COT insert. This gives the
compressed air hose more room to be moved. In certain circumstances, the COT insert may
need to be loosened and pulled out slightly to the front.
CAUTION
Do not pinch the cable.
Make sure that you do not pinch or damage the cables run at the back (connected to the FCU).
ETP feeder unlock device [03088220-xx]
Inside circlip pliers, bent tips J01 [00365186-xx]
Service Work
3.10.4 Replacing the Unlocking Pins [03088220-xx] COT insert
Service Manual SIPLACE SX4/DX4 175
Removal
Dismantle the feeder unlocking device. (See "3.10.3 Replacing the 40-Fold Feeder Unlock Device
[03011582-xx]" [ ➙ 173])
Installation
Follow the removal instructions in reverse order for installation.
Use the inside circlip pliers to remove the circlip.
CAUTION!
Under the circlip you will find a spring (2).
Make sure that the circlip and the upper guidance bush-
ing do not blow away and get lost.
Use the snipe pliers to remove the unlocking pin.