SM-131-006.pdf - 第129页
Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH -1 Chapter 5 Head Section 7. MSB W hole Cleaning and Lubricat ion Procedures (10) Detach 12 top blocks . (See Fig. E56 below) - Manage to dis…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
- Tenderly pull out the linear measure sensor in detaching operation and disconnect the
connector.
- Cleanly remove the screw lock (Three Bond 1401B) remained last time that why the
screw lock protruded from the bolt section has adhered to the attaching surface. If
omitting this operation, it may cause some problems such as the height of the linear
measure sensor is different from the setting.
Fig. E54
(9) Attach the head section attaching jig (A lid for protecting nozzle shaft jumping out) to
the head and with using a tap hole for the large diffusion plate as shown in Fig. 55 below.
Fig. E55
View of Head Bottom Surface
No.1 Nozzle
Connector
! Caution
! Caution
Maybe, the screw
lock applied last time
has remained here.
Back Surface
Front Surface
View of Head Bottom Surface
No.1 Nozzle Position
No.1 ノズル
M1.6×L4
Head section
attaching Jig
Back Surface
0605-001
5-27

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(10) Detach 12 top blocks. (See Fig. E56 below)
- Manage to distinguish the shaft setting position of the top blocks detached.
- Do not drop M1.6×L3 bolts into the head inside when removing the top blocks and, in
just case, cover the floor with the rag prepared. (Pull it out in a straight line)
- Clean up the top block detached with a rag or etc.. Check the both surfaces to attach the
shaft and the top block if the screw lock adheres and when you found the screw lock
remained, surely remove it, otherwise it may bring about some troubles.
Fig. E56
Front View
Side View
Top Block
When you found the
screw lock remained
around here, please
remove it cleanly.
M1.6×L3
1 2
3
4 5 6
7
8 9 10 11 12
Line up these top blocks in order.
Pull out it in a
straight line and
detach it.
0605-001
5-28

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(11) Remove 3-M1.6×L4 mounting bolts for attaching the bottom rotor as shown in
Fig. E57 and detach the nozzle shaft assy (bottom rotor) from the DD motor.
Fig. E57
The following Fig. E58 is showing the condition that the nozzle shaft assy (bottom rotor)
has already been removed from the DD motor.
Fig. E58
No.1 Nozzle Position
View of head Bottom Surface
No.1 ノズル
M1.6×L4
Nozzle Shaft
Assy
0605-001
5-29