SM-131-006.pdf - 第154页
Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH-1 Chapter 6 Backup Base Section 1. Replacement of Backup Base Motor 1.6 Flatness Confirmation of Backup Base (1) Fix the backup base with the…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
Chapter 6 Backup Base Section
1. Replacement of Backup Base Motor
Motor Bracket 4
250
Fig. F3 Belt Tension
Timin
g
Pulle
y
S20
1.3 Backup U/D and Timing Belt
Measure the arrow-marked position with
a digital tensometer and confirm that the
tension becomes "59 to 69 N (6.0 to 7.0
kgf)".
• When the measured tension value
differs from the specified one, adjust
the tension with Motor Bracket 4.
(Rotate the pulley and measure
several spots. Connect the jig and
release the brake.)
Set Value for Tensometer:
Width = 12 mm
Unit Weight = 0.25 gf/cm
2
Span = 250 mm
1.4 Leveling of Ball Spline
While keeping the motor braked and Phase C detected, use the slot (Timing Pulley S20) to
adjust the dimension (the distance up to the upper surface of Spline Shaft S16) for
"232.0±0.2 mm" and the parallelism of Points A, B, C, and D on the shaft for "0.01 mm or
less".
1.5 Setting Confirmation of Lower Limit Mechanical Stopper
Attach Lower Limit Mechanical Stopper
S29 to Base 1.
At this time, the dimension between the
stopper mounting face of the base and the
stopper rubber end must be "36.0 mm (35.5
to 36.0 mm).
35.5 to 36.0
Mechanical
Stopper S29
Base 1
Fi
g
. F4 Sto
pp
er Bolt
0406-001
6-2

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
Chapter 6 Backup Base Section
1. Replacement of Backup Base Motor
1.6 Flatness Confirmation of Backup Base
(1) Fix the backup base with the bolts (M6L16), SW, and FW so that the positioning pin
can be located outside.
(2) Apply a dial gauge to in Bases a and b and confirm that the total flatness of a and
b is "0.1 mm or less".
Base a
Base b
Positioning Pin
M6L16
M6L16
M6L16
M6L16
Fig. F5 Flatness of Backup Base
0406-001
6-3

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
2. Replacement of Backup Base Servoamplifier
Chapter 6 Backup Base Section
2.1 Location of Servomotor Amplifier (Driver)
2.2 Detachment of Servoamplifier
(1) Disconnect the connectors (CN1A, CN1B, CN2, and CN3) located on the front side
of the servoamplifier.
(2) Detach the power line located under the servoamplifier.
Supply 200 V AC : L1, L2, and L3
Control 200 V AC : L11 and L21
Motor : U, V, W, and PE
(3) Detach the servoamplifier from the panel. (fastened by screws)
Cutter Axis A63 in Section A
Cutter Axis A63 in Section B
NA Section
Backup Axis A53
Fig. F7 Side 1 below Main Body (BA Block)
Cutter Axis A63 in
Section D
Cutter Axis A63 in
Section C
NC Section
Backup Axis A53
Fig. F8 Side 3 below Main Body (BC Block)
0406-001