Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
Bus cable is faulty.
(Cause 1) Bus cable disconnected.
(Remedy) Connect correctly.
(Cause 2) Bus cable fault
(Remedy) Change the cable.
(Cause 3) Noise enter bus cable.
(Remedy) Take measures against noise.
(Cause 4) Termination connector disconnected.
(Remedy) Connect termination connector.
34 CRC error
(Cause 5) The same No. exists in the servo amplifier side axis
setting.
(Remedy) Set correctly.
Input frequency of command pulse is too high.
(Cause 1) Command given is greater than the maximum speed
of the servo motor.
(Remedy) Review operation program.
(Cause 2) Noise entered bus cable.
(Remedy) Take action against noise.
35 Command
frequency error
(Cause 3) Servo system controller failure
(Remedy) Change the servo system controller.
17-17
0506-001
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
Bus cable or printed board is faulty
(Cause 1) Bus cable is disconnected.
(Remedy) Connect the connector of the bus cable.
(Cause 2) Bus cable fault.
(Remedy) Change the cable.
(Cause 3) Printed board is faulty.
(Remedy) Change the servo amplifier.
36 Transfer error
(Cause 4) Termination connector disconnected
(Remedy) Connect termination connector.
Parameter setting is wrong.
(Cause 1) Servo amplifier fault caused the parameter setting to
be rewritten.
(Remedy) Change the servo amplifier.
37 Parameter error
(Cause 2) There is a parameter whose value was set to outside
the setting range by the controller.
(Remedy) Change the parameter value to within the setting
range.
17-18
0506-001
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
A linear servo control error was detected.
(Cause 1) The mounting direction of the linear scale is not
matching.
(Remedy) Check the mounting direction of the linear scale.
Review the settings (Linear Scale Electronic
Gears) of Parameter Nos. 65 and 66.
Check the linear scale control error detection level
+F67.
(Cause 2) The motor worked with Servo ON.
(Remedy) Confirm that the motor has stopped and set
"Servo ON" again.
(Cause 3) Initial Magnetic Pole Detection Not Executed
(Remedy) Execute the initial magnetic pole detection.
42 Linear Servo
Control Error
Detection
(Cause 4) The resolution of the linear scale signal is different from
the specified one.
(Remedy) Review the settings (Linear Scale Electronic
Gears) of Parameter Nos. 65 and 66.
Check how the linear scale is mounted.
Main circuit device overheat
(Cause 1) Servo amplifier faulty.
(Remedy) Change the servo amplifier.
(Cause 2) The power supply was turned on and off
continuously by overloaded status.
(Remedy) Review the drive method.
45 Main circuit
device overheat
(Cause 3) Air cooling fan of servo amplifier stops.
(Remedy 1) Change the servo amplifier or cooling fan.
(Remedy 2) Reduce ambient temperature.
17-19