SM-131-006.pdf - 第291页
Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH-1 Chapter 17 Servo Alarm 1. Troubleshooting on Servo Alarm Alarm Codes Contents of Servo Alarm Cause and Remedy Stopped by the interference c…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
(1) The travel in the group exceeded the maximum value
"999999999".
(2) When "1: Alarm Stop" is selected as a speed excess
processing control, a value exceeding the speed limit is
allocated for the group composing axes.
41 Line intrpl point
data error
(Remedy) Set the correct data.
(1) The auxiliary axis is set in the "RUN" mode.
(2) The auxiliary axis is set in the "ALARM" mode.
(3) The auxiliary axis is set in the "READY OFF" mode.
(4) The auxiliary axis is set in the "SERVO OFF" mode.
(5) The external running stop signal and the running stop
signals (STP, RSTP) are "ON".
42 Err of start line
intrpl asst axisr
(Remedy) Remove the cause of the alarm from the auxiliary
axis.
The number of axis self is set for the interference check and
check stop axes.
43 Interference chk
setup Err
(Remedy) Review the set value for the control parameter
Pr.20E.
The interference check alarm condition was established at
the starting.
44 Interference
check Error
(Remedy 1) Confirm that the correct value is specified as
the parameter related to the interference check.
(Remedy 2) Change the operation pattern such that no
interference check error can occur.
The collision prevention alarm condition was established
during the operation.
45 Collision prevent
Error
(Remedy 1) Confirm that the correct value is specified as
the parameter related to the interference check.
(Remedy 2) Change the operation pattern such that no
collision prevention error can occur.
17-29
0506-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
Stopped by the interference check stop axis. 46 Interference chk
stop axis
(Remedy)
The driving mode was changed under the condition that
prohibits the mode change of the parallel driving axis.
50 Pal dr mode
chng uncorrect
(Remedy) Change the driving mode only when the
requirements for the change are fulfilled.
The zeroing, the automatic, or the linear interpolation
operation was performed in the asynchronous fine
adjustment mode of the parallel driving axis.
51 Pal dr
asynchronous
mode
(Remedy) Perform the zeroing, the auto, or the linear
interpolation operation in the synchronous mode.
(1) A zeroing method other than the scale origin signal
detection type is selected for the zeroing operation of the
parallel driving axis.
(2) No pair axis relative to the parallel driving axis group No.
is specified.
Or, the same parallel driving group No. is specified for
more than 3 axes.
52 Pal dr axis setup
Error
(Remedy 1) Select the zeroing method (described in the left
column) for the zeroing method of "Zeroing
Option 1".
(Remedy 2) Set the corresponding parallel driving axis
group No., making a pair.
As for the parallel driving axis, the deflection between the
master and slave axes exceeded the parallel driving
deflection excess range.
53 Pal dr deflection
is excessive
(Remedy) Perform an adjustment so that the deflection
between the master and slave axes can decrease.
In addition, review the deflection excess width of
the parameter and the delay of the excess
deflection detection start.
17-30
0506-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
When an error was corrected at "Servo ON" in the
synchronous mode of the parallel driving, the deflection
exceeded the effective synchronization range of the
parameter.
54 Pal dr sync and
effect wd is
illegal.
(Remedy) Review the synchronous effective width of the
parameter.
The machine was started during error correction at "Servo
ON" in the synchronous mode of the parallel driving.
55 Pal dr sync
matches
executing
(Remedy) Do not perform the startup operation while the
synchronization signal is "ON".
The following errors occurred on the slave axis side while
the machine was running in the synchronous mode of the
parallel driving.
(1) Servo Alarm
(2) Servo OFF, Ready OFF (Including the emergency stop)
(3) Communication Error or Power OFF
56 Pal dr slave axis
is abnormal.
(Remedy) Remove the cause of the error from the slave axis
side.
While the parallel driving was being zeroed, the deviation
between the master and slave axes exceeded the tolerance
width.
57 Pal dr gap corr
allow wd
exaggerated
(Remedy 1) Perform an adjustment so that the mechanical
deviation between the master and slave axes can
stay within the tolerance wide.
(Remedy 2) Set correct values for the parallel driving
zeroing signal offsets (Pr.023C and Pr.023D).
The stop command was entered during error correction at
"Servo ON" in the synchronous mode of the parallel driving.
58 Pal dr sync
matches illegal.
(Remedy) The synchronization will be interrupted and the
zeroing will not be completed.
Perform the zeroing operation again.
17-31
0506-001