Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH-1 When the machine is delivered or transferred under normal condition, it is not required to perform any teaching operations on the following…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
2.3.7 Nozzle Level Offset
This session describes how to teach the relative positional relation between the master nozzle and
the other nozzles.
• Procedure for Teaching Operation
(1) Attach the nozzles to be used.
(2) Select one of the [1], [2], [3], and [4] buttons in the "Select head" group box of the
"NOZZLE LEVEL OFFSET" window and the [All nozzle] or the [Designate nozzle]
button. (Operation Sequence: [MAINT.] Button → [TEACHING] Button → [NOZ LVL
OFFSET] Button)
(3) Select the [Teach Start] button and press the [START] button.
(4) Follow the same procedure for "[1] through [4]" in the "Select head" group box.
(5) Select the [End] button.
The "Confirmation to Saving" dialog box opens. Select the [Yes] button.
The teaching session is terminated.
Heads
2. Installation Offset
1-14
0403-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
When the machine is delivered or transferred under normal condition, it is not
required to perform any teaching operations on the following items.
2.3.8 Head Rotational Angle Axis Offset
Teaching after Replacement of Head Unit and Nozzle Axis Assembly
• Procedure for Teaching Operation
(1) Use the φ6 nozzles (4 pcs.) for "1", "4", "7", and "10". (HA09)
(2) Set the nozzle IDs to be used in the "Placement Head/Nozzle Data" window. (Operation
Sequence: [SUPV] Button → [SYSTEM] Button → [EDIT] Button entitled " Placement
Head/Nozzle Data" → "Nozzle Data" Button).
Be sure to check the dimensions in the nozzle type data.
(3) Attach the φ6 nozzles (4 pcs.) to the "1", "4", "7", and "10" positions.
(4) Select one of the [1], [2], [3], and [4] buttons in the "Select head" group box of the
"HEAD ROTATE AXIS" window. (Operation Sequence: [MAINT.] Button →
[TEACHING] Button → [OTHERS] Button → [HD ROT AXIS OFST] Button)
(5) Select the [Teach Start] button and press the [START] button.
When an error occurs after the first teaching operation, refer to the graphic
image and enter "Pre-Rotate Setting" values. After that, press the [Teach Start]
button again.
(6) Follow the same procedure for "[1] through [4]" in the "Select head" group box.
(7) Select the [End] button.
The "Confirmation to Saving" dialog box opens. Select the [Yes] button.
The teaching session is terminated.
2.3.9 Component Recognition Camera Offset (Magnification Teaching)
Teaching after Replacement of Component Recognition Camera
• Procedure for Teaching Operation
(1) Put the magnification teaching jig depository on the component recognition camera.
(2) Place the magnification teaching jig on the jig depository. (Same as IX and CX)
Do not select the [Teach Start (Offset Data)] button.
(3) Select one of the [1], [2], [3], and [4] buttons in the "Select camera" group box of the
"COMPONENT RECOG CAMERA OFFSET" window. (Operation Sequence: [MAINT.]
Button → [TEACHING] Button → [OTHERS] Button → [CMP RECOG CAMR OFST]
Button)
(4) Select the [Teach Start (Mag instruction)] button and press the [START] button.
(5) Follow the same procedure for "[1] through [4]" in the "Select camera" group box.
(6) Select the [End] button.
The "Confirmation to Saving" dialog box opens. Select the [Yes] button.
The teaching session is terminated.
Heads
2. Installation Offset
1-15
0403-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
2.3.10 NL-Axis Origin Offset
When the cam follower transition detection function is used, it is required to perform a teaching
operation on the NL-axis origin offset.
• Procedure for Teaching Operation
(1) Attach the nozzles to be used.
(2) Select one of the [1], [2], [3], and [4] buttons in the "Select head" group box of the "NL-
AXIS ORIGIN OFFSET" window and confirm that "1" is set in the "Designate Noz" text
box in the "Designate Noz" group box. (Operation Sequence: [MAINT.] Button →
[TEACHING] Button → [OTHERS] Button → [NL-AXIS ORG OFFSET] Button)
(3) Select the [Teach Start] button and press the [START] button.
(4) Follow the same procedure for "[1] through [4]" in the "Select head" group box.
(5) Select the [End] button.
The "Confirmation to Saving" dialog box opens. Select the [Yes] button.
The teaching session is terminated.
When the offset is more than 0.1 mm, the error is indicated in yellow.
In this case, it is required to check the nozzle shaft and the surroundings of the
cam follower.
Heads
2. Installation Offset
1-16
0403-001