SM-131-006.pdf - 第56页
Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH-1 2. Installation Offset 2.1 Input Procedure • When the machine is delivered or transferred under normal condition, follow the procedures des…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
0403-001
Model ItemGXH-1
1.2 Leveling
• With the four pedestals (1 through 4) being mounted, adjust the X and Y directions.
(1) Adjust the pedestals for Level Vials a and b to detect that the machine is installed
horizontally in Direction Y.
(Target in Direction Y: within one graduation)
The jigs (flat plates) are required for the level vials because they are placed on the linear
guides.
Confirm that Level Vials c and d can also detect the horizontal installation of the
machine.
(2) Adjust the pedestals for Level Vials A and D to detect that the machine is installed
horizontally in Direction X.
Depending on outward warpage, the equal graduations can be allocated to both A and D.
(3) Lock four pedestals (1 through 4).
(4) Reconfirm that the machine is installed horizontally in both X and Y directions. (Level
Vials A, D, a, b, c, and d)
(Target in Direction Y: within one graduation)
• With the six pedestals (1 through 6) being mounted, adjust the X and Y directions.
(1) Lock Pedestals 5 and 6 and confirm that Level Vials A and D for Direction X and Level
Vials a, b, c, and d for Direction Y can detect the horizontal installation of the machine.
When Pedestals 5 and 6 are adjusted too high for the X-direction
adjustment, Pedestals 1 through 4 may be raised afloat.
Installation Procedure
1. Leveling
1-2

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
2. Installation Offset
2.1 Input Procedure
• When the machine is delivered or transferred under normal condition, follow the
procedures described in "2.2 Manual Offset" and "2.3.1 through 2.3.7" in "2.3
Automatic Offset".
(1) Zero all axes.
• When the conveyors are not activated in the zeroing operation, perform remote
teaching operations on the PCB detection sensors.
(2) Open the "Output Chk" tab sheet and select the [Block 5] button. (Operation Sequence:
"MAINT." Button → "DVC CHECK" Button → [INP/OUT] Button → "Output Chk"
Tab Sheet)
(3) Select the [CNVRL] or the [CNVRR] button.
(4) Select the [D2] and [D3] buttons in the "Select Bit" group box.
[D2]: PCB Detection Remote Sensor 1 (Deceleration) Remote [NA] or [NB]
[D3]: PCB Detection Remote Sensor 1 (Stop) Remote [NA] or [NB]
(5) Press the [ON/OFF] button in the "Control Sw" group box.
(6) Confirm that the light emission of the PCB detection sensor is turned ON and OFF.
(Execution of Teaching Operation, Completion)
The light emission of the sensor is
turned ON and OFF.
Fig. A4 PCB Detection Sensor
Installation Procedure
2. Installation Offset
1-3
0403-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
2.2 Manual Offset
• Detach the feeder position indication cover on each stage beforehand.
2.2.1 Head Level Offset (Each Head)
(a) It is required to release the [STAGE READY] switches because this maintenance
work must be performed with the doors being opened.
(b) Confirm that the nozzle up/down axes are zeroed.
• Attachment of Master Nozzle (No. 1 Nozzle Position)
(1) Move the head to a position where the nozzle can easily be attached.
(1.1) Enter "1" in the "Nozzle No." text box for
"Designate nozzle". (Operation Sequence:
[MAINT] Button → [TEACHING]
Button → [NOZ LVL OFFSET] Button)
(1.2) Select the [Nozzle placement position
move] button and press the [START]
button.
(2) Attach the nozzle to the nozzle No. 1 position. (See Fig. A5.)
Be careful not to make the nozzle and your finger touch the linear
measure sensor section.
(3) After the master nozzle has been attached, perform a zeroing operation for the nozzle.
(3.1) Select one of the [Block 1], [Block 2], [Block 3] and [Block 4] buttons in the
"MOTOR" window. (Operation Sequence: [RETURN] Button → [DVC
CHECK] Button → [MOTOR] Button)
(3.2) Select the [DD] button.
(3.3) Select the [Sel axis] button and press the [START] button.
Origin Attachment
Position Position
Operator Side
Fig. A5 Nozzle Position
Heads
2. Installation Offset
1-4
0403-001