Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 138 8.17 Vision Measurement before and after Dipping As default, the Vision measur ement is performed afte r dipping. As of this station soft wa…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
137
8.16 Checking Board Position after Placement
In the station software it can be checked if the board position has been changed during placement.
With this check an additional measurement of each board position (result of the fiducial
measurement) is performed after placement and this measurement is then compared to the original
measured position.
The feature can be enabled / disabled via two new options under Settings Machine options
Fault detection.
Figure 8-10: Checking board position after placement
Remeasure fiducials after placement
With this option the two fiducials per board that are placed most distantly from each other will be
measured and compared to their measured values during the first board detection.
If the distance exceeds the set tolerance value (here 0.1 mm) the station software stops with an
error message. The board cannot be released from the processing area until the operator has
confirmed the error.
Check plausibility of fiducial distances
The nominal distances between the fiducials in SIPLACE Pro are compared to their measured
distances. The comparison is performed per panel.
If the difference exceeds the set tolerance value (here 0.5 mm) the machine stops, and the
operator is prompted to teach the fiducials.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
138
8.17 Vision Measurement before and after Dipping
As default, the Vision measurement is performed after dipping. As of this station software version,
the Vision measurement can optionally be performed before and after dipping.
Thus, slipped components can be detected and the position corrected after dipping.
The option is set in SIPLACE Pro.
8.18 Smart Pin Support Fast Configuration Change
If an existing pin configuration on the lifting table shall be replaced by a new pin configuration, the
pins will not be put back into the pin magazine anymore. Instead of that the existing pins will be
moved on the lifting table. This shortens the time for the configuration change.
Detailed information can be found in the User Manual Smart Pin Support, item no. [00197001-xx].
8.19 New Feeder Types
The station software supports the new feeder types that are described in the following sections.
8.19.1 Multiple JEDEC Tray Feeder
The new Multiple JEDEC Tray Feeder is supported by the station software on the SX1/SX2 V2
and the SIPLACE X-series S placement machines. This feeder resembles the "Traystack Feeder
AX" feeder and supports additionally:
Different component types within one feeder
14 or 18 waffle pack trays per cassette
Retrofitting of the entire cassette
On the SIPLACE X-series S placement machines the Multiple JEDEC Tray Feeder is set up on the
manual MTF 40 X component table.
On the SX1/SX2 V2 placement machine the feeder is set up on the special MTF 60 X table in the
WPC feed device.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
139
In SIPLACE Pro there are two feeder types for this feeder:
Feeder type in
SIPLACE Pro
Features
Max.
component
height +
magazine
Feeder type in station software
Multiple JEDEC
Tray Feeder 14
14 levels / waffle
pack trays
12.0 mm
Multiple JEDEC Tray Feeder
Multiple JEDEC
Tray Feeder 18
18 levels / waffle
pack trays
7.6 mm
Multiple JEDEC Tray Feeder
Table 8-1: Feeder types Multiple JEDEC Tray Feeder
The feeder type with 14 levels per cassette is provided to transport tall components. There is no
difference between the feeder types with 14 or 18 levels per cassette in the station software, the
full capacity with 18 levels per cassette is always assumed. At the station Multiple JEDEC Tray
Feeder is displayed as feeder type for both types.
If the Setup verification is not used, the level settings of the concerned waffle pack trays also
remain at the station after a reboot.
NOTICE
It is not intended to omit any levels for tall components. Instead, the different cassette
types shall be used.
8.19.2 JEDEC Tray Stack Feeder
The new JEDEC Tray Stack Feeder is supported on the SX1/SX2 V2 and the SIPLACE X-series S
placement machines. This feeder resembles the "Traystack Feeder AX" feeder but is equipped with
a longer feed axis.
The JEDEC Tray Stack Feeder can be set up at the same positions as the Multiple JEDEC Tray
Feeder.
8.19.3 SIPLACE Wafer Systems 12 1&3 and 12 2&4
The SIPLACE Wafer Systems 12 1&3 and 12 2&4 are supported on the CA-series placement
machines. Please refer to section 8.1.