SIPLACE Station Software 7xx to 714 介绍.pdf - 第60页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 60 6.26 Supported Placement Heads The station software supp orts the C&P12, C&P20A and Twin He ad placement heads on the DX- series plac…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
59
6.24 Machine Behavior at Cover Foil Torn
In previous station software versions the placement heads get stopped when a cover foil torn
occurs and this always causes a machine stop. As of this station software version the machine
behavior has been specifically configured for the placement heads as follows:
C&P20A Machine stop
Twin Head No machine stop
CPP No machine stop
C&P12 No machine stop
Features for the DX-Series (V705.03)
The station software supports the new DX1/DX2 and DX4 placement machines that are based on
the corresponding SX1/SX2 and SX4 placement machines. The features of the 705.03 station
software version for the DX-series are listed in the sections 6.25 to 6.29.
6.25 General
The DX1/DX2 placement machines differ from the SX1/SX2 placement machines as follows:
B C&P12 placement head instead of CPP placement head.
The 27x27 reject bin and the left reject channel fail.
If two C&P12 placement heads exist, there are two machine zero points.
If the placement head shall be omitted via the configuration, it must be selected in the Auto-
configuration, whether the omitted placement head is a Twin Head/C&P20A or a C&P12.
Support of DX-tables and changeover tables.
The DX1/DX2 placement machines cannot be upgraded with regard to the number of gantries.
The number of gantries is already selected during the software installation and is not part of the
Auto-configuration.
During the first booting after installation of the station software, the following options must be
selected manually in the Auto-configuration fort he DX-series placement machines:
For the C&P12 placement head: height position (altitude)
Lamp indicator (two-colored or three-colored)
Table positions:
60 slots (inner position)
60 slots (outer position)
30 slots (outer position) with 30 slots + free location for tray or WPC
NOTICE
No upgrade from DX to SX!
No head or gantry modularity, i.e. no remodeling is performed from one head or
gantry type to another in the field.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
60
6.26 Supported Placement Heads
The station software supports the C&P12, C&P20A and Twin Head placement heads on the DX-
series placement machines. The DX1 placement machine is delivered with one of these placement
heads optionally. The DX2 placement machine is delivered with the optional placement head
configurations C&P12/C&P12, Twin Head/C&P12, C&P12/C&P20 or C&P20A/C&P20A. The DX4
placement machine is delivered with the C&P20A placement head (4x).
6.26.1 C&P12 Placement Head
Detailed information on the new C&P12 placement head (service positions, nozzle changer
configurations etc.) can be found in the User Manual to SX1/SX2 and DX1/DX2 (as of 705).
6.27 Conveyor Types for DX-Series
Analog to the conveyor for the SX1/SX2 placement machines, the conveyor for the DX1/DX2
placement machines consists of the following three sections: input section, placement section and
output section.
The conveyor for the DX4 placement machine consists of the following five sections: input section,
placement section 1, intermediate section, placement section 2 and output section.
For the DX-series placement machines solely the single lane conveyor is supported. The fixed rail
of the single lane conveyor can be mechanically mounted at several positions. Other features, such
as transporting boards, width adjustment, loading boards into the input section via the GUI are
identical to the conveyor types for the SX-series.
6.28 Support of Long Boards on DX4
The Long Board option is supported for the DX-series placement machines in the same way as for
the SX-series placement machines but up to 550mm length, see section 6.4.
6.29 DX-Table for DX-Series
The DX-table consists of a part that is fixed installed in the machine and has the same mechanical
interfaces as the changeover table and is screwed together with the machine frame as well. The
upper part of the table can be removed from the machine.
Just every second slot is equipped with an EDIF interface (EDIF = Electronic Design Interchange
Format). Thus, feeders may only be placed on the odd track numbers between 1 and 60 and no
even track numbers are displayed on the GUI.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
61
Features (V705.04: Compatible Mode V704.03)
6.30 Flexible Usage of Feeder Types
As of this station software version some feeder types can be flexibly used without changing the
setup in SIPLACE Pro. After a feeder type change the machine can immediately start picking up
again.
The following feeder type pair is supported for flexible usage:
2x8mm X-feeder 8mm X-feeder
The Status display X-feeders topic has been completed accordingly in the online help of the
station software.
6.31 Enhancement of SIPLACE Smart GUI
The SIPLACE Smart GUI has been enhanced as follows:
Optimized assistance after pick-up failure.
New icon Waiting for PCB
This icon is displayed, if the machine waits for a board.
New stopwatch board counter function
With this function it is possible to measure the number of produced boards in a given period of
time. A stopwatch counter and the period of time, since the measurement was started are
displayed.
The function can be started via the Stopwatch board counter button and stopped via the
Reset button in the GUI settings view.
6.32 SST38 PCB Camera Replaced by SST30
The SST30 PCB camera now covers the entire functionality of the SST38 PCB camera. Thus, it is
possible to measure 01005 components without any restrictions with the SST30 PCB camera as of
this station software version.
Features (V705.04 SP1 and SP2: Compatible Modes V704.03 SP1
and V704.03 SP2 respectively)
6.33 Improved traveling range measurement
In this station software version, the traveling range measurement has been improved. For this
reason, you are advised to recalibrate the traveling ranges during installation of the station
software.