SIPLACE Station Software 7xx to 714 介绍.pdf - 第79页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 79 7.20 Changed User Guidance at Pickup Errors As of this station software version the user guidance at pickup erro rs and the corresponding dea…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
78
Example
In the following Random Setup scenario, the components on Track 1, 2 and 3 may have dynamic
alternatives on the Tracks 1, 22 and 23 respectively. The feeder on Track 21 (32mm) is not
required for the current product. When the feeder has been removed from Track 2, the feeder on
Track 22 shall be put back onto Track 2.
Figure 7-14: Feeder was removed from Track 2
Figure 7-15: Feeder on Track 22 shall be put back onto Track 2
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
79
7.20 Changed User Guidance at Pickup Errors
As of this station software version the user guidance at pickup errors and the corresponding
deactivation of the feeders has been changed.
At pickup errors (i.e. for every deactivation reason) the colored marks now lead up to the setup
views and no longer to the Deactivated tracks view. For this, the Activate button has been added
to some views for the operator to handle the error in these views. The changes apply to the
following views:
Figure 7-16: Setup view for X-table
The Locking menu with the selection Lock/Unlock.
The Activate button is new and is activated if the operator can activate the selected track (in
the Current graphic).
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
80
Figure 7-17: Setup view for MTC / WPC
The Activate button is new and is activated if the operator can activate the selected tray.
Figure 7-18: Setup view for manual ray
The Locking menu with the selection Lock/Unlock.