SIPLACE Station Software 7xx to 714 介绍.pdf - 第26页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 26 SIPLACE Interface (variant) ✓ ✓ ✓ ✓ The option is displayed in the configuration GUI. Together with Quad Lane only SMEMA interface is possibl…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
25
4.10 Supported Hardware Options with an Interface to Station
Software 703
Feature
X2
X3
X4
X4i
X4i (HCU/
GCU
SX1/
SX2
Additional information
Nozzle changer CPP
Nozzle changer
C&P20A
Nozzle changer
TwinHead
Placement head HFH
Gripper for TwinHead
Component cameras:
Type 28, 29, 38
Stationary, type 25
Stationary, type 33
Stationary, type 36
PCB cameras:
Type 24
Type 34
Single conveyor, right
side fixed (default)
Single conveyor, left
side fixed (variant)
Flexible dual conveyor,
right side fixed (default)
Flexible dual conveyor,
left side fixed (variant)
Mechanical stopper on
single conveyor
The stopper to use can be set. In the
Manual Operations view the set
stopper can be unloaded for
adjustment.
Mechanical stopper on
dual conveyor
The stopper to use can be set. In the
Manual Operations view the set
stopper can be unloaded for
adjustment.
Long board option
Thick boards
See section 4.13.4
Heavy boards
See section 4.13.5
PCB detection during
width adjustment
Hint on the GUI
PCB barcode for 1D
codes
PCB barcode for 2D
codes
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
26
SIPLACE Interface
(variant)
The option is displayed in the
configuration GUI. Together with Quad
Lane only SMEMA interface is
possible.
Manual tray
WPC5
See section 4.15
Splice detection X-
feeder
Changeover table for X-
feeder
Component level
indicator
"IPTE Multi Stick
Feeder"
8x88 mm X-feeder
8-16
mm
8-16 mm
2x8 mm X-feeder
Reject conveyor with X-
adapter
Label feeder with X-
adapter
Stick feeder with X-
adapter
Dip module for X-tables
(LDU_X)
Vacuum pump option
for C&P20A placement heads
Mapping plate
See section 4.20
ACT
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
27
Features for SX-Series (V703.01)
The station software supports the new SX1/SX2 placement machine (with one or two gantries).
4.11 Nozzle Changer Configuration (TwinHead, C&P20A, CPP)
Depending on the built-in hardware devices and their positions (e.g. placement head type,
stationary cameras, table position outside/inside), different nozzle changer configurations are
possible on the SX1/SX2 placement machines. The mechanically available magazine carrier
locations, the nozzle reject bin and centering station, and the available reject boxes for components
and nozzles are parts of the nozzle changer configuration. Four magazines per magazine carrier
and up to four magazine carriers per gantry are available.
4.11.1 Magazine Carrier Numbering
The magazine carrier numbering on the SX1/SX2 placement machine is defined as follows:
3 4
1 2
Conveyor
2 1
4 3
Figure 4-1: Magazine carrier numbering on the SX1/SX2 placement machine
The figure displays the maximal number of magazine carriers and their numbering on the SX1/SX2
placement machine. Depending on the built-in hardware, all magazine carriers are not always
available. In principle, the available magazine carrier locations differ, if the table is installed inside
or outside and if a WPC or stationary cameras are available.
Only the magazine carrier locations that are mechanically available are displayed on the GUI. The
following example displays the available magazine carrier locations, if the table is located outside.