SIPLACE Station Software 7xx to 714 介绍.pdf - 第189页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 189 By clicking the Stop button, the execution of scripts is paused and the Stop button changes to a Continue button. When the user clicks the C…

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
188
The Test bench inspection button opens the correspondent tool wizard. Reports are automatically
stored to the preconfigured C:\Sirio\Protocols\<Head-Type> directory from where they can be
collected by SIPLACE Pro Line Diagnostics.
10.9.3 Head Verification View
The Head verification view is available as of the Advanced Production activity level.
The C&P20 A, C&P20 M, C&P20 P and CPP placement heads can be verified.
Figure 10-12: Head verification view
NOTICE
Nozzle changer configuration available on Advanced Production activity level!
Changing nozzles and adapting the nozzle changer configuration is part of the head
verification workflow. Therefore, the nozzle changer configuration is also available on the
Advanced Production activity level (previously on the Customer service activity level
only).
This applies for all customers even if they do not use the Head verification feature!
When selecting a placement head, the Prerequisites view is filled, and the Cancel button enabled.
The machine checks whether the required nozzles are available in the nozzle changer. If not, the
quantity of missing nozzles is displayed. Calibration tools cannot be detected by the machine, so
the user is asked to verify the presence of the calibration tool. When all nozzle prerequisites are
fulfilled, the Start button is enabled.
By clicking the Start button, the Stop button is enabled the head selection disabled and the scripts
are executed in sequence. If any nozzles are disabled, the user is asked whether to enable them.
In the results view, the currently running script is displayed as well as the overall results of
completed scripts. If a script has an overall failed result, the results for the single segments are
displayed. Anytime during execution of the scripts, pop-up windows can be displayed, requesting
information or actions by the user.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
189
By clicking the Stop button, the execution of scripts is paused and the Stop button changes to a
Continue button. When the user clicks the Continue button, the execution of scripts is continued.
Whenever the user clicks the Cancel button, the initial state of the dialog is restored (confirmation
requested).
When the last script is finished, the Stop button changes to a Done button and the Generate
report button is enabled. When clicking the Generate report button, the user is asked for the user
name and a comment that are stored together with the script results. The report is stored in the
C:\Sirio\Work\MaintenanceReports directory from where it can be collected by SIPLACE Pro Line
Diagnostics.
By clicking the Done button, the initial state of the dialog is restored.
10.10 Station Software GUI Improvements
The station software GUI has been improved as follows:
The Reset all changes button has been entered in the detailed error view for pickup errors.
It is now possible to jump between the normal error view and the detailed error view without
having to solve the detailed error completely first.
Figure 10-13: Switching between error views
The user can switch between the error views by clicking the arrow at the top bar. Within the
detailed error window, all solutions for solving the problem are listed for selection.
The machine name used in SIPLACE Pro is displayed in the info bar at the bottom of the main
view of the station software GUI. This field is only filled when a production job has been
downloaded.
The Inspect pickup window is now the same in the detailed error view as in the feeder
settings view.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
190
The Single calibration view has been redesigned as follows:
Figure 10-14: Single calibration view
The new view is separated into one part for the calibration results and one part for segment
selection. If no selection is necessary, the table will be expanded to full size. Every calibration
step displays the results in an individual table. A calibration step can be selected in the combo
box and executed by pressing the Execute single calibration button.
SIPLACE Vision is active only while executing the calibration. The images of the camera are
displayed in a detailed result window.