SIPLACE Station Software 7xx to 714 介绍.pdf - 第236页

Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition 236 Features (V711.1 (R18 -1): Compatible Mode 710.3) 12.11 SIPLACE TX V2 – New Placement Machine Compatible mode: Hidden The new SIPLACE TX V2 …

100%1 / 290
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
235
12.8 Using Two Dip Modules for Dipping
Compatible mode: Complete
If two LDU dip modules are positioned on the same table and have the same type of flux medium
and same cavity depth, the station software uses both dip modules to dip components. The
components of one head-cycle are distributed on both dip modules.
12.9 Enhanced FCCS Tool
Compatible mode: Complete
The FCCS tool has been enhanced to support camera verification of camera types SST47 and
SST25 in combination with the CPP placement head.
12.10 Enhanced SIPLACE Vision Functionality
NOTICE
Detailed information on the SIPLACE Vision functions can be found in the online help of
the station software.
SIPLACE Vision has been enhanced as follows:
The QR barcode type is supported. All QR barcodes of the 18004 ISO/IEC norm with format
Model 2 are supported.
Compatible mode: Compatible
To avoid that an incorrect barcode is read for traceability purposes, the user can define
conditions for the barcode in the Vision system. If a barcode does not fulfill all conditions, the
Vision system looks for another barcode with valid conditions in the region of interest. The
conditions are saved in SIPLACE Pro.
Compatible mode: Hidden
The Component Shape wizard supports teaching groups and regular grids of THT round pins
and THT square pins.
Compatible mode: Compatible
The new camera types SST48 and SST49 are supported. Please also refer to section 12.13.
Compatible mode: Hidden
Improved display of measuring steps on the GUI.
Compatible mode: Complete
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
236
Features (V711.1 (R18-1): Compatible Mode 710.3)
12.11 SIPLACE TX V2 New Placement Machine
Compatible mode: Hidden
The new SIPLACE TX V2 placement machine supports placement on a dual conveyor system and
is available in three configurations: TX1 V2 (single gantry), TX2 V2 (dual gantry) and TX2i V2 (dual
gantry, inner table). The dual conveyor can be used as single conveyor in Flexible Dual Lane mode
when boards with at width > 260 mm are placed. In this case, the Flexible Dual Lane Machine
Connection Bound license is required.
The new multi touch monitor is supported at the SIPLACE TX V2 placement machine. For this, a
new customized logoff is required. This will be done by a shortcut on the desktop. The logoff
command and the shortcut will be copied to the station computer with the new WES7 Configurator
version.
Additionally, the virtual keyboard can be disabled in the GUI Settings dialog.
12.11.1 Switching Off Cover Fan and Vacuum Pump Fan
The cover fan and vacuum pump fan of the SIPLACE TX V2 placement machine are switched off
automatically under certain circumstances. This will reduce the noise emission and save energy.
In the event of a long machine idle time, the vacuum pump is automatically switched off. After a
120 second cooling period, the fans of the cover and vacuum pump will be switched off. By
switching on the vacuum pump, the fans will be switched on again.
The Automatically switch off the compressed air option must be enabled.
The fans will not be switched off if the vacuum pump is switched off temporarily, e.g. for zero
pressure adjustment.
12.12 SIPLACE C&P20 P2 New Placement Head
Compatible mode: Hidden
The new SIPLACE C&P20 P2 placement head is supported on the SIPLACE TX V2 placement
machine. A new 6xxx nozzle series has been introduced for this placement head. This nozzle
series is also supported by the C&P20 P placement head.
12.13 SST48 and SST49 New Camera Types
Compatible mode: Hidden
The GigE camera types SST48 and SST49 are supported for the C&P20 M2, C&P20 P and C&P20
P2 placement heads.
For calibration of the SST49 camera, a new calibration tool must be used. This calibration tool can
be used for all cameras and requires new nozzle types as described below.
Station Software 7xx to 714.0 (R20-2) / Feature Description 11/2020 Edition
237
Nozzle type
Placement head
Camera type
4335
C&P20 P
C&P20 M2
SST49
6335
C&P20 P2
SST49
4235
C&P20 P
C&P20 M2
all other camera types
6235
C&P20 P2
all other camera types
12.14 SIPLACE SmartFeeder Xi New X-Feeders
To support the high placement performance of the SIPLACE C&P20 P2 placement head, new X-
feeders have been introduced: SIPLACE SmartFeeder Xi 4 mm, 8 mm and 2 x 8 mm.
These feeders are compatible with the correspondent previous SmartFeeder X-feeders. The feeder
types remain unchanged in the software. However, their maximum performance depends on the
placement head that uses the feeder.
Using a SIPLACE SmartFeeder X together with the SIPLACE C&P20 P2 placement head may lead
to decreased placement performance since the SIPLACE SmartFeeder Xi provides optimizations
that only work together with this placement head. In other situations, both feeders behave identical.
12.15 Linear Dipping Unit 2 X New Dipping Module
Compatible mode: Compatible
The station software supports the new Linear Dipping Unit 2 X that exists in two variants:
Linear Dipping Unit 2 X for X-tables
Linear Dipping Unit E for E-tables on E-series machine only
The Linear Dipping Unit 2 X can be used alternatively to the existing Linear Dipping Unit X and set
up physically wherever the existing SIPLACE Pro setup requires the former model, with one
exception: it cannot be used at the SWS.
The Linear Dipping Unit 2 X can be inserted fully assembled or not assembled on the changeover
table.
The Linear Dipping Unit 2 X needs a reference run and the flux medium a warm-up cycle process.
After the reference run, the operator must check that the dipping module is fully assembled, fill the
dipping module with flux medium and start the warm-up cycle process. Thereafter, the Linear
Dipping Unit 2 X is ready for production in the station software.
The number of squeegee cycles for the warm-up cycle (default: 30) and the squeegee speed
(default 200 mm / s) must be specified in SIPLACE Pro and will be transmitted to the station
software.
The Linear Dipping Unit 2 X is completely operated via the station software GUI in the feeder
Setup view. The following activities can be performed in the Dipping area and Planarity tabs of
the Feeder settings:
Starting a squeegee cycle
Starting a warm-up cycle
Starting a reference run
Adjusting and checking the planarity of the dip plate