3 Installation 3.14 Installing station software 7xx on the coplanarity computer 124 Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020 Fig.60: Configurator: Installation 3 ► Select the configu…

3 Installation
3.14 Installing station software 7xx on the coplanarity computer
Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020 123
3.14 Installing station software 7xx on the coplanarity
computer
Connecting the mouse, keyboard, monitor, and installation medium
► Switch the station computer off before you install the coplanarity computer.
► Unplug the keyboard from the station computer.
► Use the USB extension to connect the keyboard to the coplanarity computer.
► Connect the following components to the coplanarity computer:
– DVI extension to the monitor
– Keyboard to the USB extension
– Installation medium (e. g. USB stick)
Installing the operating system
► Before you install the software, you will need to define a few settings in the coplanarity com-
puter BIOS. Read the relevant installation guide.
► Start the coplanarity computer.
► Install the operating system on the coplanarity computer. This software was supplied with the
line.
Installing the station SW
Fig.58: Configurator: Installation 1
► Log into Windows as the administrator:
Login: ASM_admin
.
► Insert the installation CD "SIPLACE
WES7 Configurator" into the CD drive.
► Start the start.hta file.
► Select your BoxPC model (e.g. iBase
ABP 402-A).
Fig.59: Configurator: Installation 2
► Select the software platform 7xx
(Sirio).

3 Installation
3.14 Installing station software 7xx on the coplanarity computer
124 Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020
Fig.60: Configurator: Installation 3
► Select the configuration 70x Coplan
Vision computer.
ð The "Coplan Vision Computer" in-
stallation will be started.
► Follow the instructions on the screen.
► After successful installation, remove
the CD.
► Insert the station software CD. If the
station software does not start automat-
ically, run the EXE file from the station
software CD.
Fig.61: SIPLACE Choice Center dialog
► Go to the SIPLACE Choice Center
dialog and click on the Coplan Vision
computer(1) icon, to start the installa-
tion.
► Acknowledge all following popup win-
dows with Accept
, until the installation
has been completed.
► Check the network settings for the LAN
connection. The connection must be
set to Connected
.
► If the connection is not set to Connec-
ted, make sure that the LAN cable has
been correctly connected to the station
computer.
Fig.62: Device manager
► Perform a restart.
► Check the Devices Manager (System
Control), to make sure that the camera
link card from National Instruments(1)
has been properly recognized.
► Shut down the computer and switch off
the machine.

3 Installation
3.15 Reconnecting the Station Computer
Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020 125
3.15 Reconnecting the Station Computer
Fig.63: Win7 adhesive label
► Reconnect the monitor and keyboard to
the station computer.
► Wire the machine according to the ori-
ginal configuration.
► Switch the station computer on again.
► Stick the Win7 label (1) supplied onto
the supply unit, so that it is easily seen,
next to or under the coplanarity com-
puter label.
3.16 Configuring the LAN card in the station computer (from
Hxxxx)
► Switch on the machine.
On the station computer, configure the IP settings for the LAN card as follows:
► Log on as administrator.
► Connect the LAN cable of the coplanarity computer [03103204‑xx] to X3 (see overview of con-
nections3.10
"Fitting the station computer (from Hxxxx)" [}115]).
ð In the Control Panel → Network and Internet → Network Connections menu, you now
find two new network connections (Local Area Connection).
ð The connection that is not connected is indicated by a red cross.
► The connection that is connected does not have a red cross. Rename this connection into
"Connection to machine LAN".
► Configure the IP address 192.168.255.249 and the subnet mask 255.255.255.240 for this
connection.