1.3.3.2 Important measures to protect against static charging
Most plastics can easily become charged and must therefore be kept away from at-risk com-
ponents.
Always ensure that people, the workplace and packaging are safely earthed when handling
electrostatic sensitive components.
1.3.3.3 Handling ESD modules
As a general rule: Only touch electronic modules if you must carry out work on the modules. In that
case, make sure that you do not touch the pins or printed conductors when you pick up flat mod-
ules.
Only touch components if you are earthed by one of the following measures:
You are wearing an ESD wristband.
You are wearing ESD shoes.
You are wearing ESD shoe earthing strips on an ESD floor.
Immediately before you touch an electronic module, discharge your own body by touching a con-
ductive and earthed object (such as unpainted parts of a switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not move the assemblies near to data view devices, monitors or television units. Keep a min-
imum distance of 10 cm to monitors.
1.3.3.4 Measurements and modifications to ESD modules
Only perform measurements on modules if one of the following conditions is fulfilled:
You are using an earthed measuring device (e.g. via PE conductors).
You are using a potential-free measuring device and discharge the measuring head before
the measurement (e.g.by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
1.3.3.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1 Introduction
1.4 Staff qualifications and training
Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020 93
1.3.4 Release History
Document
SIPLACE X-Series S
3D sensor
Assembly instructions
Release Amendments
02/2014 Initial release
06/2016 Amendments, supplements:
Safety instructions on SMPS
Classification of the optical systems
Safety instructions for the sensor of the coplanarity module
X module (GigE, SMPS)
Scope of delivery
Adhesive label for sensor module
GCU and MGCU connections
Installing the LAN card in the station computer
Installing main memory in the coplanarity computer
Lockout attachment
Cabling the coplanarity computer
Setting up the coplanarity computer
06/2020 Amendments, supplements:
Safety instructions (updated)
Scope of delivery (updated)
BoxPC ABP402-A, iBase, incl. conversion plug-in card support (supplemen-
ted)
(replaces: control computer BoxPC 627C [03094731‑xx])
GCU/MGCU overviews (updated)
Connection of LAN cable from coplanarity - to station computer (supplemen-
ted)
Installing station software 7xx at the coplanarity computer (updated)
Description of boards (supplemented)
Circuit diagrams for Hxxxx (updated)
1.4 Staff qualifications and training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
1 Introduction
1.4 Staff qualifications and training
94 Assembly Instructions / Montageanleitung SIPLACE X-Series S 3D-Sensor 06/2020