5.1 Replacing the NC-Motor The NC motor is responsible for changing the nozzle size on each of the machine’s placing heads. Nozzle change is only performed if the next pickup operation requires a different sized nozzle. …

100%1 / 158
Chapter 5
NC-Axis
Objective:
Given a CP-7-series machine,
technical documentation and
required tools, remove, replace and
calibrate the NC-motor to FUJI
specifications.
5.1 Replacing the NC-Motor
The NC motor is responsible for changing the nozzle size on each of the machine’s
placing heads. Nozzle change is only performed if the next pickup operation
requires a different sized nozzle.
Any failure of the NC-motor and nozzle holder clutches to align will result in
various NC related problems. NC-motor adjustments should be carried out in the
following situations.
- After replacement of the NC-motor.
- After replacement of the NC tension belt
Required Tools: 1 Set of Allen Wrenches
1 Phillips Screwdriver
Required Jig: Nozzle Axis Alignment Jig
ADCPJ8040
CP7T35002
NC Motor
CP7T35001
Chapter 5 5.1 Replacing the NC-Motor
Edition 2.0 5-1 CP-7-series Level 3 Tutorial
Resolution: 0.002 mm/pulse World (Zero)
Affected Calibration data: NC Origin Pos. MC0ZOVNC
5.1.1 Removing the NC-Axis Motor
Procedure:
1. Turn OFF the machine power.
2. Disconnect both electrical connections to the motor.
3. Remove the four (4) allen bolts securing the motor to the mounting
bracket and carefully remove.
4. Separate the gear from the motor by loosening the set screw and remove.
Caution
Ensure that a back-up of Proper data is taken prior to replacing the
motor.
CN001
Chapter 5 5.1 Replacing the NC-Motor
Edition 2.0 5-2 CP-7-series Level 3 Tutorial