9.1.6 Editing USL and LSL
Press [Maintenance] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] - [Result] -
[Edit USL/LSL] to display the following screen.
9.1.6.1 Set
Press [Set] to the left of the item to be edited, and input the setting using the numerical
keypad.
9.1.6.2 Cp and Cpk Calculation Functions
The functions to calculate Cp and Cpk are as follows.
Ave: Average amount of misalignment
σ: Standard deviation
USL: Upper limit
LSL: Lower limit
Cp =
Cpk = Cp x 1 -
USL - LSL
6 x σ
USL + LSL
2
- Ave
USL - LSL
2
CP7T39006
Chapter 9 9.1 PAM
Edition 2.0 9-6 CP-7-series Level 3 Tutorial
9.1.7 Displaying the Distribution
Press [Maintenance] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] - [Result] -
[Indicate Distribution] to display the following screen. A measurement results diagram
for each nozzle can be displayed.
9.1.7.1 Changeover of Data Display
The display can be switched to the standard distribution display.
9.1.7.2 Changeover of Nozzle Display
The nozzle display can be switched.
9.1.7.3 Changeover of Head Display
The placing head display can be switched.
CP7T39007
Chapter 9 9.1 PAM
Edition 2.0 9-7 CP-7-series Level 3 Tutorial
9.1.8 Updating the Machine Data
Press [Maintenance] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] - [Renewal]
to display the following screen. The measurement results can be fed back to the machine
data.
9.1.8.1 Changeover of Nozzle Display
Press this button to toggle through the nozzles (1 to 6). The necessary data for each
nozzle is also displayed as each change of nozzle is made.
9.1.8.2 Update Proper
The measurement results can be fed back to the machine data. Depending on the level of
compensation, the measurement results can be used in full (1/1) or as a half (1/2).
9.1.8.3 1/1
Press this button to feed the measurement results back to the machine data as they are.
9.1.8.4 1/2
Press this button to feed 0.5 of the measurement results back to the machine data.