CP7 Series Level3 Tutorial Manual.pdf - 第126页

Chapter 8 Parts Cameras Objective: Given a CP-7-series machine, technical documentation and required tools, remove, replace and calibrate the W ide and Narrow cameras to FUJI specifications.

100%1 / 158
Notes:
Chapter 7 7.3 Training Evaluation
Edition 2.0 7-8 CP-7-series Level 3 Tutorial
Chapter 8
Parts Cameras
Objective:
Given a CP-7-series machine,
technical documentation and
required tools, remove, replace and
calibrate the Wide and Narrow
cameras to FUJI specifications.
8.1 Parts Cameras
These CCD cameras are mounted on the machine for inspection of the parts picked
at the first station. The raw image is captured by the cameras and compared with
part related data in part data to ensure that the part’s dimensions (within specified
tolerances) are correct (refer to the figure below).
Problems arising from an incorrectly positioned/calibrated camera include
uniformly displaced parts, high error rate due to problems occurring during image
acquisition, and uniformly skewed parts.
Recalibration of the parts cameras is needed to correct the above mentioned
problems. Some examples of possible reasons for calibration are:
- lens replacement
- camera replacement
Required Tools: 1 Set of Allen Wrenches
1 dial gauge
Required Jig: Calibration jig
10st cam lever spring stopper jig
H
Narrow
Wide
CP7T38001
Chapter 8 8.1 Parts Cameras
Edition 2.0 8-1 CP-7-series Level 3 Tutorial