CP7 Series Level3 Tutorial Manual.pdf - 第145页

9.1.4 Measuring the P AM Placement Press [Maintenance] - [PAM Measure] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] to display the following screen and enable the START button. Press START to begin the measurement…

100%1 / 158
9.1.3.3 Measuring the Accuracy of Placement
The [PAM Measure] command is used to measure the accuracy of placement, when the
placement of PAM parts is complete. The loader commands must be used to load and
unloaded the panels. Ensure measurement is carried out with the XY-table at its lower
limit.
9.1.3.4 Loading and Unloading Panels
The [Panel Loader] command is used to load and unload panels.
9.1.3.5 Carrying Out PAM at the Machine
The following procedures are for the measurement of placement accuracy, and updating
of the machine data.
Carrying Out PAM With the Cam Speed at 80% and Updating
the Machine Data
1. From the main screen, press [Maintenance] - [PAM Measure], and then
set the cam speed to 80%.
2. Select [PAM Equip] and START to carry out the placement of the PAM
parts.
3. Press [PAM Measure] and START to carry out measurement of the
placement accuracy.
4. Press [Renewal] to update the machine data.
Carrying Out PAM With the Cam Speed at 100% and Updating
the Machine Data
1. From the main screen, press [Maintenance] - [PAM Measure], and then
set the cam speed to 80%.
2. Select [PAM Equip] and START to carry out the placement of the PAM
parts.
3. Press [PAM Measure] and START to carry out measurement of the
placement accuracy.
4. Press [Renewal] to update the machine data.
Note: Make sure that the program selected is suitable for production at a cam speed of 100%.
Chapter 9 9.1 PAM
Edition 2.0 9-3 CP-7-series Level 3 Tutorial
9.1.4 Measuring the PAM Placement
Press [Maintenance] - [PAM Measure] - [PAM Measure] - [100%/80%] - [OK] - [PAM
Measure] to display the following screen and enable the START button. Press START to
begin the measurement. The vision monitor displays during the measurement.
9.1.4.1 Move Mode
Measurement can be carried out in Continue or Step mode.
9.1.4.2 Result
The deviation results for the measurement of PAM part placement are given for each
sequence as 3s, 6s, Max., Min., Cp and Cpk.
9.1.4.3 Indicate Distribution
The distribution diagrams of the measurement results display.
9.1.4.4 File Save
The results are saved as a file.
The results files are saved at "\Fuji\User\Data" in order with the names "Pam001.Dat" to
"Pam005.Dat". The format of the files is described later in this document.
9.1.4.5 Renewal
The results are used to update the machine data placement offset items.
9.1.4.6 Editing Offset Tolerances
The offset tolerances can be edited.
CP7T39004
Chapter 9 9.1 PAM
Edition 2.0 9-4 CP-7-series Level 3 Tutorial
9.1.5 Displaying the Measurement Results
Press [Maintenance] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] - [Result] to
display the following screen. The results for all the measurements display (Avg., 3s, 6s,
Max., Min., Cp, Cpk).
9.1.5.1 Change Nozzle
The nozzle display can be changed.
9.1.5.2 Edit USL/LSL
The data (USL, LSL) can be set for the calculation of Cp and Cpk.
9.1.5.3 Show Deviation
The measurement results for each sequence are displayed.
CP7T39005
Chapter 9 9.1 PAM
Edition 2.0 9-5 CP-7-series Level 3 Tutorial