➤ After " MEASURE MA ZERO POS." has been performed, t he K-N-L is alr eady installed as required for the following proc edure. 1. Select the m ain menu option " DETERMINE CAMERA OFFSET" and proceed as…

100%1 / 138
8.6 DETERMINE CALIBRATION FACTORS OF HEAD CAMERA
This measuring routine is -together with "DETERMINE CAMERA OFFSET" - a precondition for "glass
mapping" on HS-180 machines (placement station and adhesive station II).
1
. After this main menu option is selected, the ICOS computer is synchronized, the fiducial data are
loaded and sent to the ICOS computer the display for
conveyor width adjustment
appears
:
Adjust conveyor to the PCB width subsequently used (see section 5.1.19) select "END".
2.
The following screen display appears:
PLEASE PLACE A PC BOARD OVER THE SENSOR OF THE INPUT CONVEYOR
Place the PCB above the light barrier of the input conveyor. The PCB is conveyed to the center conveyor.
3.
A
graphical display
of the position of the calibration plate and the following prompt are displayed:
PLACE CALIBRATION PART ON MOTHERBOARD
PLEASE PRESS <START> KEY
Performance of the action:
Open the protective cover take a hold of the calibration plate by the outer
edges only (!) check the calibration plate for oxidation or contamination: All metal surfaces must have the
same coloring replace the calibration plate with a new one, if necessary place the calibration plate
ex-
actly
in the upper right corner of the PCB (as shown on the screen) check the position of the
points
rela-
tive to the direction of travel close protective cover switch on the control press the "Start" button.
4.
The graphic is cleared from the screen and the following display:
’TEACH’ CAMERA INTO THE MIDDLE OF THE FIDUCIAL
USE TEACH-PANEL
TEACHING IS ON, ’END’ TO FINISH
Performance of the action:
"Teach" the PCB camera in
X-Y
-direction until the crosshairs on the scre-
en of the evaluation unit are positioned centrally with respect to the image of the calibration plate
press "END" on the teach panel.
5.
The
calibration factors are determined and displayed
: Proceed as described in section
7.14, from
point 9 onwards
.
6.
If the measurement was
successful
and after pressing "RETURN" (= transfer to the main memory), the
following display appears on the screen:
PLEASE REMOVE PCB FROM OUTP. CONV.
Performance of the action:
Remove the PCB incl. the calibration plate from the output conveyor
display of the main menu transfer the values determined to the work diskette by selecting
"STORING"
.
Continue with "DETERMINE CAMERA OFFSET".
8.7 DETERMINE CAMERA OFFSET and ADHESIVE NEEDLE OFFSET
This measuring routine is used to determine the camera and dispensing needle offsets.
Prerequisite for this routine: The
calibration factors
of the head camera must have already been deter-
mined (see section 8.6).
8 AutoCal Procedure: Routine Check on HS-180 Adhesive Station II User’s Manual AutoCal Program
8.6 DETERMINE CALIBRATION FACTORS OF HEAD CAMERA Software Version 114.xxx
8 - 4
After "MEASURE MA ZERO POS." has been performed, the K-N-L is already installed as required for the
following procedure.
1. Select the main menu option "DETERMINE CAMERA OFFSET" and proceed as described in section 8.6
above, points 1 and 2. The PCB is conveyed to the center conveyor.
2. First the procedure for determining "CAMERA OFFSET" follows, the following screen display appears:
-FIX PLASTICINE ON PCB
- EXCHANGE ADH. CARTRIDGE FOR KLEBER-NULLPUNKT-LEHRE (K-N-L)
PLEASE PRESS <START> KEY
The placement head is moved to the left (as seen in direction of PCB travel).
Performance of the action: apply the plasticine to the
center of the PCB remove the right-hand cartridge (= cartridge adjacent to fixed conveyor side)
MA-install zero point insert for adhesive station II ("K-N-L" ) on the rightpress the "Start"button.
3. After pressing the "Start" button the following display appears on the screen:
- ’TEACH’ K-N-L OVER PLASTICINE
- AFTER ’END’ AN IMPRESSION IN THE PLASTICINE IS CREATED
TEACHING IS ON, ’END’ TO FINISH
Performance of the action: Teach the tip of the "K-N-L" (adhesive station zero point gauge) above
the plasticine press the "END" button on the teach panelthe Z-axis is lowered once an im-
pression in the plasticine is produced the Z-axis is raised again.
4. The following screen display appears:
-’TEACH’ CAMERA INTO THE MIDDLE OF THE RIGHT IMPRESSION
TEACHING IS ON, ’END’ TO FINISH
Performance of the action: Using the X-Y knobs of the teach panel, position the previously created
impression so that it is centered in relation to the crosshairs (screen of the evaluation unit) press
"END" on the teach panel the calibration factors determined are displayed and transferred to the
main memory after pressing "RETURN".
5. The measuring procedure for determining the "ADHESIVE NEEDLE OFFSET" follows automatically and
the following screen display appears:
- EXCHANGE LEFT ADH. CARTRIDGE FOR KLEBER-NULLPUNKT-LEHRE (K-N-L)
- ’TEACH’ K-N-L OVER PLASTICINE
PLEASE PRESS <START> KEY
The placement head is moved to the left again (as seen in direction of PCB travel).
Performance of the action (analogous to point 2 above): now install the K-N-L in place of the left car-
tridge press the "Start" button.
6. The instructions how to proceed further are displayed:
- ’TEACH’ K-N-L OVER PLASTICINE
- AFTER ’END’ AN IMPRESSION IN THE PLASTICINE IS CREATED
TEACHING IS ON, ’END’ TO FINISH
Performance of the action: Create new impression proceeding as described above under point 3!
Users Manual AutoCal Program 8 AutoCal Procedure: Routine Check on HS-180 Adhesive Station II
Software Version 114.xxx 8.7 DETERMINE CAMERA OFFSET and ADHESIVE NEEDLE OFFSET
8 - 5
7. The following display appears on the screen:
- ’TEACH’ CAMERA INTO THE MIDDLE OF THE LEFT IMPRESSION
TEACHING IS ON, ’END’ TO FINISH
Performance of the action (analogous to point 4 above): Teach the camera so it is centered above the
left impression press the "END" button on the teach panel the new and old values for "CAMERA
NOZZLE OFFSET" and "ADHESIVE NEEDLE OFFSET" are displayed and transferred to the MA-Data of
the work diskette after "RETURN" has been pressedthe PCB is conveyed to the output conveyor.
Remove the PCB from the output conveyor, the main menu is displayed. Select "STORING".
8. Now remove (= before glass mapping is carried out!) the MA-zero point insert (K-N-L)! The two adhesive
cartridges are not to be installed yet! = precautionary measure to protect the glass mapping plate!.
Thereafter continue the Routine Check with the menu option "glass mapping" (see section 8.5).
8.8 AXES MOVEMENT MENU
This menu only serves for testing purposes, error isolation and the adjustment of the X / Y-axes.
When carrying out the Routine Check, this menu is only required if a deviation > 2 counts was obtained du-
ring the initially performed axis adjustment (see "CHECK AXIS ADJUSTMENT").
All details regarding the use of the AXES MOVEMENT MENU are contained in the description of this
menu option in section 5.1.20.
Look up all safety instructions applicable during the performance of this menu in section 2.3!
8.9 I/O MENU
This menu is only selected for testing purposes and error isolation.
Skip this menu option when carrying out the Routine Check.
All details regarding the use of the I/O MENU are contained in the description of this menu option in section
5.1.21.
Read the safety instructions contained in section 2.4 prior to the execution of this menu option.
In particular, take heed of the WARNING in section 2.4 upon the concurrent setting of outputs!
8 AutoCal Procedure: Routine Check on HS-180 Adhesive Station II User’s Manual AutoCal Program
8.8 AXES MOVEMENT MENU Software Version 114.xxx