Additionally required testing aids: • Plasticine Supply source: Siemens AG AUT 5 V Serv ice Rupert-Mayer-Str . 44 D-81359 München Tel. 089/722 61200 FAX: 089/722 24260 Us er’ s Ma nual Auto Cal Prog ram 3 R equirem ents …

3.4 Prerequisites for MS-102, MS-128 and MS-132
3.4.1 System Requirements
• Winchester
• Interface Software V 2.5 and higher
• Station Software from MSX.200.xxx
• Axis Card Software Version 2.5 and higher
• BASIC from version 6.0 (contained on the hard disk/Winchester)
NOTE:
The new HP printer requires the use of BASIC Version 6.21.
This version is delivered along with the AutoCal program (see chapter 4, "Set of Diskettes").
3.4.2 Testing Aids Required
• AutoCal program, available on 2 different sets of diskettes:
—
AutoCal program on 5 DD diskettes, item no. 00322032
—
AutoCal program on 4 DD diskettes and 1 HD diskette, item no. 00322032
(For details refer to chapter 4. Supply source - see below)
NOTE
The following testing aids must be available for the performance of the Routine Check (all measuring rou-
tines are carried out). For individual checks, only the testing aids listed in chapter 9 are required.
The following testing aid are delivered along with the machine:
• Steel nozzle, type 104, item no. 00301435
• New MA-zero point gauge (with 2 holes: ∅ 3.5 mm and ∅ 5 mm), item no. 00120060
• New adjusting gauge for component table ("iron", with 2 holes), item no. 00120040
• Adjusting gauge for adhesive application head, with tip, item no. 00310314
• Teach panel, external, item no. 00132207
• Calibrating nozzle for coplanarity module, item no. 00301711
• VISION 2 Calibration plate, item no. 00132070
• 2 Test sockets for nozzle changer
*)
:
Large test socket (for special holder), item no. 00311659
Small test socket (for normal holder), item no. 02102021
• Nozzle top part = nozzle insert, item no. 00302566
*)
*) also included with nozzle changer accessories kit
Parts to be ordered:
• Nozzle adapter, type 117, item no. 00300659
• Mapping plate and centering square for MS-102/128, contained in the Mapping Case, item no. 00132040
• Mapping plate and centering square for MS-132, contained in the Mapping Case, item no. 00134100
3 Requirements for Use User’s Manual AutoCal Program
3.4 Prerequisites for MS-102, MS-128 and MS-132 Softwareversion 114.xxx
3 - 4

Additionally required testing aids:
• Plasticine
Supply source: Siemens AG
AUT 5 V Service
Rupert-Mayer-Str. 44
D-81359 München
Tel. 089/722 61200
FAX: 089/722 24260
User’s Manual AutoCal Program 3 Requirements for Use
Softwareversion 114.xxx 3.4 Prerequisites for MS-102, MS-128 and MS-132
3 - 5
This page intentionally left blank!
3 Requirements for Use User’s Manual AutoCal Program
3.4 Prerequisites for MS-102, MS-128 and MS-132 Softwareversion 114.xxx
3 - 6