00190725-01.pdf - 第128页
9.17 DETERMINE COPLANARITY COORDINAT ES ➤ The cop lana rity las er modul e is arrang ed on the op erat or’s sid e, norm ally betw een the com ponent camera and the nozzle c hanger. ➤ An approximately correct s tarting va…

9.13 AXES INITIALIZING MENU
This menu (together with the EDIT MENU)is required
only
if you had to respond to the query
"Z AXIS IN UP-
PER POSITION ?"
with
NO
upon the start of the AutoCal program (see section 7.1).
• In this case proceed as described for the HS-180 in section
7.11
.
9.14 NOZZLE MENU
➤ Observe the correct
allocation
of the nozzles (see "Adapter Coordinates" / Service Manual MS, chap.
"Station Extensions")!
➤ A prerequisite for this measuring routine is, among others:
"ANGLE CORRECTION D-AXIS"
must have
been determined!
➤ Nozzle changer on MS-1xx:
7
normal holders and
1
special holder (= different from HS-180 !)
• Perform the procedure for "DETERMINE NOZZLE POSITIONS" and "NOZZLE ENDUR. RUN"
analo-
gously
to the description for HS-180, section
7.12 and 7.13
(testing aids: see 7.12 and 7.13).
CAUTION
∆
!
To conclude, establish the
"reference status
of the nozzle changer MS-1xx" (section
10.3) !
9.15 "EXECUTE NEXT 4 POINTS" (calibration PCB Vision System)
• Perform the calibration proceeding as described for the HS-180 in section
7.14
.
• Testing aids required: see section 7.14
NOTE
➤ The jaws correction values are displayed in mm (incl. sign).
➤ The max. perm. Z and / or H-jaws correction is ± 0.20 mm and is entered in the MA-Data on MS-1xx
machines under
"JAW OFFSET X / Y"
.
• To conclude, select
"STORING"
. The new values are entered in the MA-Data on the hard disk.
9.16 COMPONENT CAMERA MENU
➤ As a rule, the component camera is located in front of the coplanarity laser module (next to the operator).
➤ Approximately correct values for the X/Y-position (in MA-Data under
"CENTERING STATION"
) should
have already been entered.
• Perform
all
menu options of the "COMPONENT CAMERA MENU" as described for the HS-180,
section
7.15
.
• Testing aids required: see section 7.15.
User’s Manual AutoCal Program 9 AutoCal Procedure: Routine Check MS-102, 128 and 132
Software Version 114.xxx
9 - 9
9.17 DETERMINE COPLANARITY COORDINATES
➤ The coplanarity laser module is arranged on the operator’s side, normally between the component camera
and the nozzle changer.
➤ An approximately correct starting value for the X/Y-position of the laser module should have already been
entered in the MA-Data (under "INK SPOT"!).
• Perform the determination of the coplanarity data as described for HS-180, section
7.15
.
• Testing aids required: see section 7.15.
9.18 AXES MOVEMENT MENU
This menu is intended for testing purposes, error isolation and the adjustment of gantry and head axes.
Within the scope of the Routine Check it is required
only if
a
deviation
> 2 counts
was obtained during the
initially performed axis adjustment (see menu option "CHECK AXIS ADJUSTMENT").
➤ All information about the
use
of the AXES MOVEMENT MENU is contained in the description of this
menu option in section
5.1.20.
➤ For all
safety instructions
displayed during the performance of this menu refer to
section 2.3
!
9.19 I/O MENU
This menu is only selected for testing purposes and error isolation.
Skip this menu option for the performance of the Routine Check.
All information about the
use
of the I/O MENU is contained in the description of this menu option in section
5.1.21.
➤ Prior to the performance of this menu option read the safety instructions contained in section 2.4 .
➤ In particular observe the
WARNING
contained in section 2.4 upon the concurrent setting of outputs!
9 AutoCal Procedure: Routine Check MS-102, 128 and 132 User’s Manual AutoCal Program
Software Version 114.xxx
9 - 10

10 Final Work After Calibration
This chapter describes all activities to be performed after the completion of the AutoCal measuring procedure.
Proceed in accordance with the applicable section listed below (10.1: HS-180 / 10.2: Adhesive Station II /
10.3: MS-1xx).
10.1 Final Work on HS-180 Placement Stations
10.1.1 On the BASIC Line Computer (from LRB 102.xxx): Loading the Files
Copy the MA_DATEI and, if applicable, the MA_ZUSATZ file with the new values and the PASSPKT_ file
created during mapping, from the work diskette to the hard disk of the line computer proceeding as descri-
bed below:
•
After "STORING" and completed calibration, remove the
work diskette
containing the created or
modified files, from the disk drive of the station computer and take the diskette to the line computer.
•
Enter the appropriate password on the line computer.
•
Starting from the main menu, select "File Functions" on the line computer.
•
Insert the work diskette containing the new data into the disk drive.
•
Copy the two files MA_DATEI and MA_ZUSATZ of the calibrated station from the work diskette to the
hard disk of the line computer by pressing successively the following function keys:
File function
→
Copy
→
Copy file
→
Next menu
→
System files
→
MA_ of station
→
Station 1 or
Station 2
→
System files
→
MA_ZUSATZ
→
read in file of the calibrated station).
NOTE
In the case of software version 2.01 (from LRB 102.xxx onward) proceed as described in the follo-
wing section, as the PASSPKT_ file is to be renamed before being read in and subsequently to be
changed back to the original name again.
•
From LRB 204.xxx onwards, save the new mapping file (PASSPKT_file) on the line computer, as follows:
File function
→
read in RP_files
→
Station 1 / Station 2.
•
Wait until the disk drive indicator lamp is extinguished.
•
Remove the work diskette from the disk drive.
User’s Manual AutoCal Program 10 Final Work After Calibration
Software Version 114.xxx 10.1 Final Work on HS-180 Placement Stations
10 - 1